Electrical System

Battery Charger -VAS5906-

~7min read

WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Note

Observe the Battery Charger -VAS5906- Operating Instructions.

  • Battery Charger -VAS5906- device description. Refer to → Chapter "Battery Charger -VAS5906- Device Description".
  • Charge the Battery -A-. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5906-".

Battery Charger -VAS5906- Device Description

Battery Charger -VAS5906-

The Battery Charger -VAS5906- was developed especially for charging the vehicle electrical system while the vehicle is on display.

It supplies for automatic charging of 3 - 300 Ah for starter batteries.

The 14.4 V maximum charging voltage is not exceeded. All electrical consumers will be supported up to 30 A by the support charging.

After the battery -A- is completely charged, the Battery Charger -VAS5906- switches into the maintenance charging for long-term operation.

The Battery Charger -VAS5906- starts automatically and does not need any adjustments. Only the charging terminals and the network cable need to be connected.

For more information. Refer to the Battery Charger -VAS5906- Operating Instructions.

W00-10798

Control Field Overview

1 - 25% charge display

2 - 50% charge display

3 - 75% charge display

4 - 100% charge display

5 - Ready-to-use display

6 - Pushing the START/STOP and Setup buttons will stop and start the charging process. Enter into the setup menu and select characteristic line type (hold for 10 seconds)

7 - Display malfunction

N27-10798

Battery, Charging with Battery Charger -VAS5906-

WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required

  • Battery Charger -VAS5906-

Procedure

- Place the Battery Charger -VAS5906- in the engine compartment or under the vehicle.

- Connect the Battery Charger -VAS5906- to the power supply.

The Battery Charger -VAS5906- is in idle, the display comes on when it is "ready to be used".

WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

Caution

  • Turn off the ignition and all electrical equipment.
  • Remove the key.

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

The charging process starts after approximately two seconds.

LEDs show the Battery -A- charge level. When all the lamps are on, the Battery -A- is charged.

When the Battery -A- is completely charged, the Battery Charger -VAS5906- automatically switches to maintenance charging.

Caution

Sparks can result if the charging terminals are removed too early. End the charging process by pressing the START/STOP button.

Battery -A- Charging, Ending

- Press the START/STOP-button.

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5906- from the power.

Solar Battery Maintainer -VAS6102A-

Solar Battery Maintainer -VAS6102A- Device Description

Solar Battery Maintainer -VAS6102A-

The Solar Battery Maintainer -VAS6102A- supports the vehicle electrical system and prevents the Battery -A- from self-discharging.

The Solar Battery Maintainer -VAS6102A- reaches a maximum voltage of 14.3 V and a maximum charge current of 255 mA.

All chargeable lead- and lead gel batteries can be charged with the Solar Battery Maintainer -VAS6102A-.

The Solar Battery Maintainer -VAS6102A- is connected to the diagnostic connection in the vehicle.

The Solar Battery Maintainer -VAS6102A- has a green LED integrated inside the frame which displays the function being performed. The brighter the LED, the higher the charging current.

It is not possible to overcharge the Battery -A- due to the integrated electronics.

W00-10800

The Solar Battery Maintainer -VAS6102A- is secured on the interior rearview mirror -1-. The bottom rests on the instrument panel -2-.

Note

The Solar Battery Maintainer -VAS6102A- must not touch the instrument panel completely. Only the bottom edge may be used for support. If it touches completely, the color of the instrument panel could change.

N27-10800

Solar Battery Maintainer -VAS610A- Maintenance Charging

Special tools and workshop equipment required

  • Solar Battery Maintainer -VAS6102A-

Procedure

- Secure the Solar Battery Maintainer -VAS6102 A- to the interior rearview mirror -1-.

- Lay the bottom on the instrument panel -2-.

Note

The Solar Battery Maintainer -VAS6102A- must not touch the instrument panel completely. Only the bottom edge may be used for support. If it touches completely, the color of the instrument panel could change.

- Pull the securing string together so that the Solar Battery Maintainer -VAS6102A- is close to the windshield.

- Connect the connector for the Solar Battery Maintainer -VAS6102A- to the vehicle diagnostic connection. Connecting is the same as with Vehicle Diagnostic Tester.

- Check the Solar Battery Maintainer -VAS6102A- functionality. The green LED must come on.

N27-10800

Severely Discharged Batteries

WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

A Battery -A- is designated as "severely discharged" if the resting voltage is less than 11.6 V.

WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Caution

  • Severely discharged Batteries -A- freeze earlier.
  • Batteries -A- that have frozen must no longer be used.

Note

  • Batteries -A- that have not been used for a long time will discharge by themselves.
  • In severely discharged Batteries -A-, the electrolyte consists almost completely of water, because the acid portion has been greatly reduced.
  • Severely discharged Batteries -A- become sulfated, meaning all of the plate surfaces of the Batteries -A- harden.
  • The sulfation process may be reversed if a severely discharged Battery -A- is recharged immediately.
  • If the Battery -A- is not recharged, the plates will continue to harden, and the ability to accept a charge will decrease. This results in reduction of battery performance.
  • Severely discharged Batteries -A- in vehicles must be replaced prior to delivery. Pre-existing damage cannot be ruled out.

Procedure

- Check the Battery -A- resting voltage. Refer to → Chapter "Battery, Charging".

- Charge the Battery -A-:

  • Battery Charger -VAS5095A-. Refer to → Chapter "Severely Discharged Battery, Charging with Battery Charger -VAS5095A-".
  • Battery Charger -VAS5900-. Refer to → Chapter "Severely Discharged Battery, Charging with Battery Charger -VAS5900-".
  • Battery Charger -VAS5903-. Refer to → Chapter "Severely Discharged Battery, Charging with Battery Charger -VAS5903-".
  • Battery Charger -VAS5906-. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5906-".