Body Electrical System
Description and operation
In this manual: Body Electrical System
~3min read
Description
An inverter is a device that transforms the DC voltage from the battery into an AC voltage (115V). The inverter can power various electrical devices that consume 150W or less, including mobile phone or notebook rechargers, audio systems, and TVs.

Inverter system Protection Function
| Item | Condition | LED Status |
| Undervoltage protection | Shuts down for safety at voltages lower than 11.3 V ± 0.3 V. | LED flickering |
| Resumes operation at 12.2 V ± 0.3 V. | LED lighting | |
| Overvoltage protection | Shuts down for safety at voltages higher than 15.5 V ± 0.3 V. | LED flickering |
| Resumes operation at 15.5 V ± 0.3 V. | LED lighting | |
| Overheat protection | Shuts down for safety if temperatures exceed 105 °C ± 10 °C. | LED flickering |
| Resumes operation at 95 °C ± 10 °C. | LED lighting | |
| Overcurrent protection | Turns OFF when overcurrent above a set point is detected. | LED lighting |
| The inverter stops for 20 seconds before it restarts. | LED flickering (20 seconds) |
|
| Turns OFF when overcurrent is detected 3 times. (Turn the AC inverter switch ON again to turn on the inverter.) | ? | |
| short circuit protection | The inverter shuts down for safety if there is a short circuit between the AC1 and AC 2 outputs during operation. | LED OFF |
| undervoltage/overvoltage shutdown protection | Shuts down at voltages lower than 10.7 V ± 0.3 V. | LED OFF |
| Shuts down at voltages lower than 16.5 V ± 0.3 V. | LED OFF |
Was this page helpful?