Air Conditioning| Item | Specification | |
| Compressor | Type | ESC33i |
| Oil Type and Capacity | OIL EOP 3.8~4.5 oz. (115~135 cc) | |
| Engine Type | BLDC | |
| Displacement | 33 cc/rev | |
| Condenser | Heat Rejection | 14,000 ± 5% kcal/h |
| A/C Pressure Sensor | Pressure Measurement Method | Voltage = 0.00878835 × Pressure (psig) + 0.5 |
| Expansion Valve | Type | Unit Type |
| Refrigerant | Type | R-134a |
| Capacity | 19.4 ± 0.88 oz. (550 ± 25 g) | |
Blower Unit
| Item | Specification | |
| Fresh & Recirculation | Operation Method | Actuator |
| Blower | Type | Sirocco |
| Speed Step | Auto + 8-Speed (Automatic) | |
| Speed Control | PWM Blower Module (Automatic) | |
| Air filter | Type | Particulate Filter |
Heater and Evaporator Unit
| Item | Specification | |
| Heater | Type | Pin and Tube Type |
| Heating Capacity | 4850 ±5% kcal/h | |
| Mode Operation Method | Actuator | |
| Temperature Operation Method | Actuator | |
| Evaporator | Temperature Control Type | Evaporator Temperature Sensor |
| A/C ON/OFF [°C(°F)] | Blower below 3rd speed ON: 2.1 ± 0.5 (37.58 ± 32.9) OFF: 0 ± 0.5 (32.0 ± 32.9) |
|
| Blower above 4th speed ON: 2.1 ± 0.5 (35.78 ± 32.9) OFF: 0.6 ± 0.5 (33.08 ± 32.9) |
||
Test yourself