Basic inspection
OVERALL SEQUENCE

• Reference 1···MWI-22, "On Board Diagnosis Function". • Reference 2···MWI-36, "DTC Index".
• Reference 3···MWI-51, "COMBINATION METER : Diagnosis Procedure".
DETAILED FLOW
1.OBTAIN INFORMATION ABOUT SYMPTOMInterview the customer to obtain as much information as possible about the conditions and environment under which the malfunction occurred.
>> GO TO 2.
2.CHECK SYMPTOM • Check the symptom based on the information obtained from the customer.• Check that any other malfunctions are present.
>> GO TO 3.
3.CHECK ON BOARD DIAGNOSIS OPERATIONCheck that the on board diagnosis function operates. Refer to MWI-22, "On Board Diagnosis Function".
Does the on board diagnosis function operate normally? YES >> GO TO 4.
NO >> GO TO 6.
4.CHECK CONSULT-III SELF-DIAGNOSIS RESULTSConnect CONSULT-III and perform self-diagnosis. Refer to MWI-36, "DTC Index".
Are self-diagnosis results normal? YES >> GO TO 5.
NO >> GO TO 8.
5.NARROW DOWN THE MALFUNCTIONING PARTS BY SYMPTOM DIAGNOSISPerform symptom diagnosis and narrow down the malfunctioning parts.
>> GO TO 8.
6.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUITSCheck combination meter power supply and ground circuits. Refer to MWI-51, "COMBINATION METER : Diagnosis Procedure".
Is inspection result OK? YES >> GO TO 7.
NO >> GO TO 8.
7.REPLACE COMBINATION METERReplace combination meter.
>> GO TO 9.
8.REPAIR OR REPLACE MALFUNCTIONING PARTSRepair or replace the malfunctioning parts.
NOTE:
If DTC is displayed, erase DTC after repair or replace malfunctioning parts.
>> GO TO 9.
9.FINAL CHECKCheck that the combination meter operates normally.
Do they operate normally? YES >> INSPECTION END
NO >> GO TO 1.