Diagnosis and repair workflow
OVERALL SEQUENCE

DETAILED FLOW
1.INTERVIEW FOR MALFUNCTIONInterview the symptom to the customer.
>> GO TO 2.
2.SYMPTOM CHECKCheck the symptom from the customer's information. Check that any symptom occurs other than the interviewed symptom.
Insufficient cooling/heating>>GO TO 3.
Refrigerant leakage>>GO TO 6.
Noise >> GO TO 7.
3.CONTROL SYSTEM DIAGNOSISPerform the system diagnosis for the A/C control system.
• Refer to HAC-44, "Work Flow". (AUTOMATIC AIR CONDITIONING: 4WD models) • Refer to HAC-135, "Work Flow". (AUTOMATIC AIR CONDITIONING: 2WD models) • Refer to HAC-216, "Work Flow". (MANUAL AIR CONDITIONING: 4WD models) • Refer to HAC-271, "Work Flow". (MANUAL AIR CONDITIONING: 2WD models)
Is A/C control system normal? YES >> GO TO 4.
NO >> GO TO 8.
4.PERFORMANCE TESTPerform the performance test. Check the operation of each part. Refer to HA-81, "Inspection".
>> GO TO 5.
5.TROUBLE DIAGNOSIS FOR UNUSUAL PRESSUREDiagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify the malfunctioning part. Refer to HA-83, "Symptom Table".
Low refrigerant charge>>GO TO 6.
Except above>>GO TO 8.
6.CHECK REFRIGERANT FOR LEAKAGESCheck refrigerant for leakages. Specify the malfunctioning part. Refer to HA-74, "Leak Test".
>> GO TO 8.
7.TROUBLE DIAGNOSIS FOR NOISEPerform trouble diagnosis for noise. Specify the malfunctioning part. Refer to HA-85, "Symptom Table".
>> GO TO 8.
8.MALFUNCTION PART REPAIRRepair or replace the malfunctioning part.
>> GO TO 9.
9.REPAIR CHECK (OPERATION CHECK)Check the operation of each part.
Does it operate normally? YES >> INSPECTION END
NO >> GO TO 2.