System setting
Temperature Setting Trimmer
DESCRIPTION
If the temperature felt by the customer is different from the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
With CONSULT-III
Perform “TEMP SET CORRECT” of HVAC work support item.

NOTE:
• When −3 °C is corrected on the temperature setting set as 25 °C the temperature controlled by A/C auto amp. is 25 °C −3 °C = 22 °C and the temperature becomes lower than the temperature setting.
• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.
Inlet Port Memory Function (REC)
DESCRIPTION
• If the ignition switch is turned to the OFF position while the intake switch is set to ON (recirculation), “Perform the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be selected. • If “Perform the memory” was set, the intake switch will be ON (recirculation) when turning the ignition switch to the ON position again.• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.
HOW TO SET
With CONSULT-III
Perform the “REC MEMORY SET” of HVAC work support item

NOTE
:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the REC memory function may be cancelled.
Inlet Port Memory Function (FRE)
DESCRIPTION
• If the ignition switch is turned to the OFF position while the intake switch is set to OFF (fresh air intake), “Perform the memory” or “Do not perform the memory” of intake switch OFF (fresh air intake) condition can be selected. • If “Perform the memory” was set, the intake switch will be OFF (fresh air intake) when turning the ignition switch to the ON position again.• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.
HOW TO SET
With CONSULT-III
Perform the “FRE MEMORY SET” of HVAC work support item.

NOTE
:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the FRE memory function may be cancelled.