Electrical & Power Control
Charging System :: Removal and Installation. Generator
In this manual: Electrical & Power Control
~1min read

| 1. | Generator bracket | 2. | Generator | 3. | "B" terminal nut |
| Front |
REMOVAL
Remove radiator assembly. Refer to Removal and Installation.
Remove cooling fan assembly. Refer to Removal and Installation.
Remove drive belt auto-tensioner assembly. Refer to Removal and Installation of Drive Belt Auto-tensioner.
Disconnect the harness connectors from the generator.
Remove generator bracket.
Remove generator bolts and nut using power tools.
Slide the generator out and remove.
INSTALLATION
Installation is in the reverse order of removal.
Temporarily tighten bolts and nut then tighten nut and bolts in the specified numerical order.

Nut 1 65 N·m Bolt 2 28 N·m Bolt 3 25 N·m
Install generator and check tension of belt. Refer to Checking Drive Belt.
Perform the following.
Make sure that generator pulley does not rattle.
Make sure that generator pulley nut is tight.
Was this page helpful?