Connect power cable (4) of UV lamp (6) to positive and negative terminals of the battery (3).
Press UV lamp switch (5) and check A/C system for refrigerant leaks. (Where refrigerant leaks occur, fluorescent leak detection dye appears in green color.)
Repair or replace parts where refrigerant leaks occur and wipe off fluorescent leak detection dye.
Use a UV lamp to check that no fluorescent leak detection dye remains after finishing work.
CHECK REFRIGERANT LEAKS USING ELECTRONIC LEAK DETECTOR
Do not allow refrigerant vapor, shop chemical vapors, cigarette smoke or others around the Nissan Murano vehicle.
Always check for refrigerant leaks in a low air flow environment so that refrigerant may not disperse when leaks occur.
Stop the engine.
Connect recovery/recycling/recharging equipment or manifold gauge set to A/C service valve.
Check that A/C refrigerant pressure is 345 kPa (3.52 kg/cm2, 50 psi) or more when temperature is 16 °C or more. When pressure is lower than the specified value, recycle refrigerant completely and fill refrigerant to the specified level.
Clean area where refrigerant leak check is performed and check for refrigerant leaks along all surfaces of pipe connections and A/C system components using electronic leak detector probe.
Repair or replace parts where refrigerant leaks are detected.
Start the engine and set A/C control in the following conditions:
A/C switch ON
Air flow: VENT (ventilation)
Intake door position: Recirculation
Temperature setting: Full cold
Fan (blower) speed: Maximum speed set
Run the engine at approximately 1,500 rpm for 2 minutes or more.
Stop the engine. Check again for refrigerant leakage. Go to step 4.
Recycle Refrigerant
Perform oil return operation. Refer to Perform Oil Return Operation. (If refrigerant or oil leak is detected in a large amount, omit this step, and go to step 2.)
Check gauge pressure readings of recovery/recycling/recharging equipment. When remaining pressure exists, recycle refrigerant from high-pressure hose and low-pressure hose.
Remove A/C service valve cap from the Nissan Murano vehicle.
Connect recovery/recycling/recharging equipment to A/C service valve.
Operate recovery/recycling/recharging equipment, and recycle refrigerant from the Nissan Murano vehicle.
Evacuate air for 10 minutes or more to remove any remaining refrigerant integrated to compressor oil, etc.
Refrigerant recycle operation is complete.
Charge Refrigerant
Connect recovery/recycling/recharging equipment to the A/C service valve.
Operate recovery/recycling/recharging equipment, and evacuate air from A/C system for 25 minutes or more.
Check the airtightness of A/C system for 25 minutes or more. If pressure raises more than the specified level, charge A/C system with approximately 200g refrigerant and check that there is no refrigerant leak. Refer to Leak Test.
If parts other than compressor are replaced, fill compressor oil according to parts that are replaced.
Charge the specified amount of refrigerant to A/C system.
Check that A/C system operates normally.
Disconnect recovery/recycling/recharging equipment. (Collect the refrigerant from the high-pressure hose and low-pressure hose of recovery/recycling/recharging equipment.)