INSPECTION
PROCEDURE
1. INSPECT FRONT CENTER ULTRASONIC SENSOR (for LH Side)
(a) Check the resistance.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
4 (BI) - 6 (EI) |
Always |
10 kΩ or higher |
4 (BI) - 1 (BO) |
Always |
Below 1 Ω |
5 (SI) - 2 (SO) |
Always |
Below 30 Ω |
6 (EI) - 3 (EO) |
Always |
Below 1 Ω |
If the result is not as specified, replace the front center ultrasonic sensor. |
 |
*a |
Component without harness connected (Front Center Ultrasonic Sensor) |
|
|
2. INSPECT FRONT CENTER ULTRASONIC SENSOR (for RH Side)
(a) Check the resistance.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
4 (BI) - 6 (EI) |
Always |
10 kΩ or higher |
4 (BI) - 1 (BO) |
Always |
Below 1 Ω |
5 (SI) - 2 (SO) |
Always |
Below 30 Ω |
6 (EI) - 3 (EO) |
Always |
Below 1 Ω |
If the result is not as specified, replace the front center ultrasonic sensor. |
 |
*a |
Component without harness connected (Front Center Ultrasonic Sensor) |
|
|
3. INSPECT FRONT CORNER ULTRASONIC SENSOR (for LH Side)
(a) Check the resistance.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
4 (BI) - 6 (EI) |
Always |
10 kΩ or higher |
4 (BI) - 1 (BO) |
Always |
Below 1 Ω |
5 (SI) - 2 (SO) |
Always |
Below 30 Ω |
6 (EI) - 3 (EO) |
Always |
Below 1 Ω |
If the result is not as specified, replace the front corner ultrasonic sensor. |
 |
*a |
Component without harness connected (Front Corner Ultrasonic Sensor) |
|
|
4. INSPECT FRONT CORNER ULTRASONIC SENSOR (for RH Side)
(a) Check the resistance.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
4 (BI) - 6 (EI) |
Always |
10 kΩ or higher |
4 (BI) - 1 (BO) |
Always |
Below 1 Ω |
5 (SI) - 2 (SO) |
Always |
Below 30 Ω |
6 (EI) - 3 (EO) |
Always |
Below 1 Ω |
If the result is not as specified, replace the front corner ultrasonic sensor. |
 |
*a |
Component without harness connected (Front Corner Ultrasonic Sensor) |
|
|
Was this page helpful?