1. INSPECT FUEL (ENGINE ROOM SIDE) PUMP ASSEMBLY

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

20 °C

0.45 to 0.55 Ω

If the result is not as specified, replace the fuel pump assembly.

*a

Component without harness connected