Installation
INSTALLATION
COMPONENTS (INSTALLATION)
Procedure | Part Name Code | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|---|
1 |
LEAK DETECTION PUMP SUB-ASSEMBLY |
- |
- |
- |
|
2 |
INSTALL CHARCOAL WITH OUTLET HOSE CANISTER ASSEMBLY |
77730B |
- |
- |
- |
3 |
FUEL TANK VENT HOSE |
77404 |
- |
- |
- |
4 |
CANISTER (CHARCOAL CANISTER ASSEMBLY) |
77740 |
- |
- |
- |
5 |
CONNECT CHARCOAL WITH OUTLET HOSE CANISTER ASSEMBLY |
77730B |
- |
- |
|
6 |
CHARCOAL CANISTER HOSE |
77759A |
- |
- |
- |
7 |
FUEL TANK VENT HOSE SUB-ASSEMBLY |
77404 |
- |
- |
|
PROCEDURE
1. INSTALL LEAK DETECTION PUMP SUB-ASSEMBLY
![]() |
HINT: Only perform this procedure when replacement of the leak detection pump sub-assembly is necessary. |
*1 |
Leak Detection Pump Sub-assembly |
*2 |
No. 2 charcoal canister filter |
(1) Engage the 2 claws to install a new leak detection pump sub-assembly to the No. 2 charcoal canister filter.
NOTICE:
- Do not allow foreign matter such as grease, oil or water to adhere to the O-rings.
- Ensure that the claws are engaged properly.
2. INSTALL CHARCOAL WITH OUTLET HOSE CANISTER ASSEMBLY
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
3. CONNECT FUEL TANK VENT HOSE
4. INSTALL CANISTER (CHARCOAL CANISTER ASSEMBLY)
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
5. CONNECT CHARCOAL WITH OUTLET HOSE CANISTER ASSEMBLY
(1) Connect the fuel tank vent hose to the canister (charcoal canister assembly).
Click here
![]()
6. CONNECT CHARCOAL CANISTER HOSE
7. CONNECT FUEL TANK VENT HOSE SUB-ASSEMBLY
(1) Connect the fuel tank vent hose sub-assembly to the canister (charcoal canister assembly).
Click here
![]()
.png)
.png)
.png)
.gif)