Removal
REMOVAL
COMPONENTS (REMOVAL)
Procedure | Part Name Code | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|---|
1 |
FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY |
77020A |
- |
- |
- |
2 |
FUEL PRESSURE REGULATOR HOLDER |
23283B |
- |
- |
- |
3 |
FUEL MAIN VALVE ASSEMBLY |
23070 |
- |
- |
|
● |
Non-reusable part |
- |
- |
CAUTION:
- Never perform work on fuel system components near any possible ignition sources.
.png)
- Vaporized fuel could ignite, resulting in a serious accident.
- Do not perform work on fuel system components without first disconnecting the cable from the negative (-) auxiliary battery terminal.
.png)
- Sparks could cause vaporized fuel to ignite, resulting in a serious accident.
HINT:
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
- Learning completes when vehicle is driven.
Effect/Inoperative Function When Necessary Procedures are not Performed
Necessary Procedures
Link
Front camera system
Drive the vehicle straight ahead at 15 km/h or more for 1 second or more.
.gif)
Stop and start system
Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes)
.gif)
- Learning completes when vehicle is operated normally
Effect/Inoperative Function When Necessary Procedures are not Performed
Necessary Procedures
Link
Power door lock control system
- Back door opener
Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch.
.gif)
Power back door system
Fully close the back door by hand.
HINT:
Initialization is not necessary if the above procedures are performed while the back door is closed.
.gif)
Air conditioning system
After the ignition switch is turned to ON, the servo motor standard position is recognized.
-
PROCEDURE
1. REMOVE FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY
Click here ![]()
2. REMOVE FUEL PRESSURE REGULATOR HOLDER
3. REMOVE FUEL MAIN VALVE ASSEMBLY
*1 |
O-ring |
- |
- |
*a |
Mesh |
*b |
Mini-clip |
(1) Using a screwdriver with its tip wrapped with protective tape, remove the fuel main valve assembly from the fuel suction tube with pump and gauge assembly.
NOTICE:
- Pull out the fuel main valve assembly carefully because the O-ring is firmly installed between the fuel main valve assembly and fuel suction tube with pump and gauge assembly.
- Do not damage the fuel suction tube with pump and gauge assembly.
(2) Remove the O-ring from the fuel main valve assembly.
NOTICE:
Do not remove the mesh and mini-clip from the fuel main valve assembly.
.png)
.png)
.png)