2gr-fks Cooling

Inspection

~1min read
INSPECTION PROCEDURE

1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY

HINT:

The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly.

(a) Immerse the thermostat in the water, then heat the water gradually.

(a) Immerse the thermostat in the water, then heat the water gradually.

CAUTION:

  • Do not your hands into the water that has been heated for the inspection.
  • Touching the heated water could result in burns.

(b) Check the valve opening temperature of the water inlet with thermostat sub-assembly.

Standard valve opening temperature:

85 to 89 °C

NOTICE:

When checking the water inlet with thermostat sub-assembly in water, keep the terminals dry. After the check, wipe the water inlet with thermostat sub-assembly dry.

If the valve opening temperature is not as specified, replace the water inlet with thermostat sub-assembly.

(c) Check the valve lift.

Text in Illustration

*a

Valve Lift

Standard valve lift:

8.0 mm (0.315 in.) or more at 100 °C

If the valve lift is not as specified, replace the water inlet with thermostat sub-assembly.

(d) Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at a low temperature (below 40 °C).

If the valve is not fully closed, replace the water inlet with thermostat sub-assembly.

(e) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

20 °C

10.54 to 14.26 Ω

If the result is not as specified, replace the water inlet with thermostat sub-assembly.

Test yourself

A quick Toyota Tacoma quiz: every answer comes with an explanation and a link to the manual page.