Refrrigerant R134a Servicing
Refrigerant Circuit with Restrictor and Reservoir
In this manual: Refrrigerant R134a Servicing
~1min read
Arrows point in direction of refrigerant flow.
A-Low pressure side of refrigerant circuit.
B-High pressure side of refrigerant circuit.

| Component | Aggregate state of refrigerant | Pressure bar (psi) positive pressure | Temperature in degrees Celsius (Fahrenheit) |
| -1- A/C compressor B-side | Gas | up to 20 (290 psi) | up to 70 (158) |
| -2- Condenser | From gas to vapor to fluid | up to 20 (290 psi) | up to 70 (158) |
| -3- Restrictor | From fluid to vapor | B-side to 20 (290 psi), A-side greater than 1.5 (21.8 psi) | B-side up to 60 (140 psi), A-side warmer than -4 (25) |
| -4- Evaporator | From vapor to gas | Greater than 1.5 (21.8 psi) | Warmer than -4 (25) |
| -5- Reservoir | Gas | ||
| -6- A/C compressor A-side | Gas |
Note In vehicles with A/C Compressor Regulator Valve -N280-, the pressure is modified on the low pressure side by the valve.Test yourself