Refer to Wiring Diagrams, Cell 89, for schematic and connector information.
Normal Operation and Fault Symptoms
REFER TO: Interior Lighting System Operation and Component Description (417-02 Interior Lighting, Description and Operation).
DTC Fault Trigger Conditions
| Trouble Code | Description | Fault Trigger Condition |
| BCM B145C: 11 |
Exterior Lamp Power Supply Output: Short to Ground |
Continuous memory and on-demand DTC that is set when the BCM detects a fault. Short to ground from the ambient lighting module power supply output circuit. |
| BCM B145C: 15 |
Exterior Lamp Power Supply Output: Short to Battery or Open Circuit |
Continuous memory and on-demand DTC that is set when the BCM detects a fault. Open or short to voltage from the ambient lighting module power supply output circuit. |
| BCM B1465:00 |
Ambient Lighting Bus 1: No Subtype Information |
Continuous memory DTC that is set when the BCM detects a fault in the ambient lighting LIN circuit. |
| BCM B1465:96 |
Ambient Lighting Bus 1: Internal Component Failure |
Continuous memory DTC that is set when the BCM detects a fault in the ambient lighting LIN circuit. |
| BCM B1467:00 |
Ambient Lighting Bus 3: No Subtype Information |
Continuous memory DTC that is set when the BCM detects a fault in the ambient lighting LIN circuit. |
| BCM B1467:96 |
Ambient Lighting Bus 3: Internal Component Failure |
Continuous memory DTC that is set when the BCM detects a fault in the ambient lighting LIN circuit. |
| BCM B153C: 11 |
Output Color Ambient Light: Circuit Short to Ground |
Continuous memory and on-demand DTC that is set when the BCM detects a fault. Short to ground from the ambient lighting module power supply output circuit. |
| BCM B153C: 15 |
Output Color Ambient Light: Short to Battery or Open Circuit |
Continuous memory and on-demand DTC that is set when the BCM detects a fault. Open or short to voltage from the ambient lighting module power supply output circuit. |
Possible Sources
- Wiring, Terminals or Connectors
- FDIM
- BCM
|
| G1 CHECK THE FDIM (FRONT DISPLAY INTERFACE MODULE) AUDIO CONTROL |
- Check the audio system operation using the FDIM controls (touchscreen).
Does the audio system operate correctly from the touchscreen?
| No |
REFER TO: Information and Entertainment System (415-00 Information and Entertainment System, General Information, Diagnosis and Testing). |
|
| G2 CHECK THE BCM (BODY CONTROL MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) |
- Using a scan tool, perform the BCM self-test.
Are DTC B1465:00, B1465:96, B1467:00, B1467:96, B145C:11, B145C:15, B153C:11 or B153C:15 present?
| Yes |
For DTC B1465:00 and B1465:96 GO to G3 For DTC B1467:00 and B1467:96 GO to G7 For DTC B145C:11 and B153C:11 GO to G11. For DTC B145C:15 and B153C:15 GO to G12. |
|
| G3 CHECK THE DOOR LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR A SHORT TO VOLTAGE |
- Disconnect the C2280F connector.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280F-58 |
.jpg) |
Ground |
Is voltage present?
|
| G4 CHECK THE DOOR LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR AN OPEN |
- Disconnect the left front door LED C574.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C574-2 |
.jpg) |
C2280F-58 |
Is the resistance less than 3 ohms?
|
| G5 CHECK THE DOOR LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR A SHORT TO GROUND |
- Disconnect the right front door LED C649.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C574-2 |
.jpg) |
Ground |
Is the resistance greater than 10000 Ohms?
| No |
REPAIR the circuit. After the repair: If no diagnostic trouble codes (DTCs) are present, CHECK the system for normal operation. If DTC U1000:00 is present, CLEAR the DTCs and REPEAT the self-test (required to enable the lamp output driver if DTC U1000:00 is present). If DTC U3000:49 is present, INSTALL a new BCM after all other DTCs have been resolved. REFER TO: Body Control Module (BCM) (419-10 Multifunction Electronic Modules, Removal and Installation). |
|
| G6 CHECK THE DOOR LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR A SHORT TO THE VOLTAGE SUPPLY CIRCUIT |
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280F-58 |
.jpg) |
C2280F-4 |
Is the resistance greater than 10000 Ohms?
|
| G7 CHECK THE FRONT FOOTWELL AND CONSOLE LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR A SHORT TO VOLTAGE |
- Disconnect the C2280F connector.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280D-31 |
.jpg) |
Ground |
Is voltage present?
|
| G8 CHECK THE FRONT FOOTWELL AND CONSOLE LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR AN OPEN |
- Disconnect the left footwell lamp C209.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280D-31 |
.jpg) |
C209-2 |
Is the resistance less than 3 ohms?
|
| G9 CHECK THE FRONT FOOTWELL AND CONSOLE LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR A SHORT TO GROUND |
- Disconnect the right footwell lamp C266.
- Ambient lamp C3509 for the floor console storage compartment.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280D-31 |
.jpg) |
Ground |
Is the resistance greater than 10000 Ohms?
| No |
REPAIR the circuit. After the repair: If no diagnostic trouble codes (DTCs) are present, CHECK the system for normal operation. If DTC U1000:00 is present, CLEAR the DTCs and REPEAT the self-test (required to enable the lamp output driver if DTC U1000:00 is present). If DTC U3000:49 is present, INSTALL a new BCM after all other DTCs have been resolved. REFER TO: Body Control Module (BCM) (419-10 Multifunction Electronic Modules, Removal and Installation). |
|
| G10 CHECK THE FRONT FOOTWELL AND CONSOLE LAMP LIN (LOCAL INTERCONNECT NETWORK) CIRCUIT FOR A SHORT TO THE VOLTAGE SUPPLY CIRCUIT |
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280D-31 |
.jpg) |
C2280C-4 |
Is the resistance greater than 10000 Ohms?
|
| G11 CHECK THE AMBIENT LAMP VOLTAGE CIRCUIT FOR A SHORT TO GROUND |
- Disconnect the C2280F connector.
- Disconnect the left front door LED C574.
- Disconnect the right front door LED C649.
- Disconnect the left footwell lamp C209.
- Disconnect the right footwell lamp C266.
- Ambient lamp C3509 for the floor console storage compartment.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280F-4 |
.jpg) |
Ground |
Is the resistance greater than 10000 Ohms?
| No |
REPAIR the circuit. After the repair: If no diagnostic trouble codes (DTCs) are present, CHECK the system for normal operation. If DTC U1000:00 is present, CLEAR the DTCs and REPEAT the self-test (required to enable the lamp output driver if DTC U1000:00 is present). If DTC U3000:49 is present, INSTALL a new BCM after all other DTCs have been resolved. REFER TO: Body Control Module (BCM) (419-10 Multifunction Electronic Modules, Removal and Installation). |
|
| G12 CHECK THE AMBIENT LAMP VOLTAGE CIRCUIT FOR AN OPEN |
- Disconnect the C2280F connector.
- Disconnect the left footwell lamp C209.
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280F-4 |
.jpg) |
C209-2 |
Is the resistance greater than 10000 Ohms?
|
| G13 CHECK THE AMBIENT LAMP VOLTAGE CIRCUIT FOR A SHORT TO VOLTAGE |
- Action:
Click to display the connectors
| Positive lead | Measurement/Action | Negative lead |
| C2280F-4 |
.jpg) |
Ground |
Is voltage present?
|
| G14 CHECK THE BCM (BODY CONTROL MODULE) OPERATION |
- Disconnect and inspect all BCM connectors and the corresponding inline connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- backed-out pins - install new pins as necessary
- Connect the BCM connectors and the corresponding inline connectors. Make sure they are installed and locked correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
| Yes |
CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this condition, STOP this test and FOLLOW the service article instructions. If no service article resolves this condition, INSTALL a new BCM. REFER TO: Body Control Module (BCM) (419-10 Multifunction Electronic Modules, Removal and Installation). |
| No |
The system is currently operating correctly. The concern may have been caused by module connections. ADDRESS the root cause of any connector or terminal concerns. CLEAR the diagnostic trouble codes (DTCs). |
|