This system is composed of the rear MICU, the HondaVAC switch, the HondaVAC motor, the HondaVAC motor relay, and the keyless buzzer.
The rear MICU controls the HondaVAC motor relay based upon one or more of the following conditions:
Vehicle ignition mode
Transmission range switch P position
Vehicle speed
HondaVAC switch ON/OFF position
Operating time of HondaVAC motor
Engine running condition
State of charge of the battery
Under certain conditions, the green LED indicator may come ON and the HondaVAC motor will either shut off or not start. In addition, the POWER SAVE indicator may turn on. See the chart below.
Power ON Indicator/POWER SAVE Indicator
Switch Appearance
Buzzer
Operation State
OFF
HondaVAC motor OFF
OFF
HondaVAC motor ON
The operating time is within 7 minutes without engine running
There in no time limit of the operating time with the engine running
Illuminated
Pattern 1
When the HondaVAC motor is actuated more than 7 minutes without the engine running
Blinking
Pattern 2
Compulsory turn off under the following conditions:
When the HondaVAC motor is actuated continuously for 8 minutes without the engine running.
Under the following conditions with the engine running while the HondaVAC motor is actuated
The state of charge of the battery is decreased
Illuminated for 60 seconds
OFF
When the HondaVAC switch is pressed in the power mode ACCESSORY under the following conditions:
The state of charge of the battery is decreased
The HondaVAC motor is actuated continuously for 8 minutes