Canister

~1min read

INSPECTION 1. Check the evaporative emission control system hoses for loose connections, sharp bends, or damage.

2. Check for deformation, cracks, and fuel leaks.

3. После снятия адсорбера проверьте его на отсутствие трещин и деформации.

3. After removing the canister, check it for cracks and deformation.

CANISTER PURGE SOLENOID VALVE

INSPECTION

Always make alignment marks on the vacuum hoses before disconnecting them, so that they can be reconnected to their original positions.

1. Disconnect the vacuum hose from the canister purge solenoid valve.

2. Disconnect the wiring harness connector from the solenoid valve.

3. Connect a hand-operated vacuum pump to the solenoid valve port from which the hose with the red stripe was disconnected.

4. Apply vacuum and check valve operation while connecting / disconnecting battery voltage to the solenoid valve terminals.

Battery voltage Normal Condition
Applied Vacuum decreases
Not applied Vacuum is maintained
5. Измерьте сопротивление между выводами электромагнитного клапана.

5. Measure the resistance between the solenoid valve terminals.

Canister purge solenoid valve:

Coil resistance: 26 Ω (at 20 °C (68 °F))

Test yourself

A quick Hyundai Elantra CN7 quiz: every answer comes with an explanation and a link to the manual page.