[DIGITAL CLOCK TYPE]
| Connector | Pin No. | Function | Connector | Pin No. | Function |
| A | 1 | BATT + (TAIL) | A | 31 | PHOTO SENSOR (-) LEFT |
| 2 | SENSOR SUPPLY (+5 V) | 32 | PHOTO SENSOR (-) RIGHT | ||
| 3 | HAZARD SIGNAL | 33 | HTD | ||
| 4 | ACC | 34 | REAR FOG LAMP SWITCH | ||
| 5 | ACTUATOR MODE (VENT) | 35 | K-Line | ||
| 6 | ACTUATOR MODE (DEF) | 36 | - | ||
| 7 | ACTUATOR F/B MODE | 37 | - | ||
| 8 | ACTUATOR INTAKE (FRE) | 38 | - | ||
| 9 | INTAKE ACTUATOR (REC) | 39 | - | ||
| 10 | INTAKE ACTUATOR F/B | 40 | SENSOR GROUND | ||
| 11 | TEMP ACTUATOR DR (COLD) | B | 1 | GROUND | |
| 12 | TEMP ACTUATOR DR (HOT) | 2 | - | ||
| 13 | TEMP ACT''R DR F/B | 3 | DEF ACTUATOR (CLOSED) | ||
| 14 | TEMP ACTUATOR PS (COLD) | 4 | DEF ACTUATOR (OPEN) | ||
| 15 | TEMP ACTUATOR PS (HOT) | 5 | DEF ACT''R F/B | ||
| 16 | TEMP ACT''R PS F/B | 6 | HUMIDITY (PWM) | ||
| 17 | C_CAN HIGH | 7 | - | ||
| 18 | C_CAN LOW | 8 | IGN2 | ||
| 19 | DELAY (+) | 9 | GROUND | ||
| 20 | ILL - (REO) | 10 | - | ||
| 21 | ION SIGNAL | 11 | BLOWER MOTOR (+) | ||
| 22 | CLEAN SIGNAL | 12 | PT (GATE) | ||
| 23 | IONIZER DIAGNOSIS | 13 | FET (DRAIN F/B) | ||
| 24 | MM_CAN HIGH | 14 | - | ||
| 25 | MM_CAN LOW | 15 | IGN1 | ||
| 26 | AMBIENT SENSOR (+) | 16 | BATTERY | ||
| 27 | - | ||||
| 28 | EVAPORATOR SENSOR (+) | ||||
| 29 | ECV + | ||||
| 30 | ECV - (GROUND) |
Components (2)
[ANALOG CLOCK TYPE]
| Connector | Pin No. | Function | Connector | Pin No. | Function |
| A | 1 | BATT + (TAIL) | A | 31 | PHOTO SENSOR (-) LEFT |
| 2 | SENSOR SUPPLY (+5 V) | 32 | PHOTO SENSOR (-) RIGHT | ||
| 3 | HAZARD SIGNAL | 33 | HTD | ||
| 4 | - | 34 | REAR FOG LAMP SWITCH | ||
| 5 | ACTUATOR MODE (VENT) | 35 | K-Line | ||
| 6 | ACTUATOR MODE (DEF) | 36 | - | ||
| 7 | ACTUATOR F/B MODE | 37 | PAB_IGN1 | ||
| 8 | ACTUATOR INTAKE (FRE) | 38 | PAB OFF SIGNAL | ||
| 9 | INTAKE ACTUATOR (REC) | 39 | SBR SIGNAL | ||
| 10 | INTAKE ACTUATOR F/B | 40 | SENSOR GROUND | ||
| 11 | TEMP ACTUATOR DR (COLD) | B | 1 | GROUND | |
| 12 | TEMP ACTUATOR DR (HOT) | 2 | - | ||
| 13 | TEMP ACT''R DR F/B | 3 | DEF ACTUATOR (CLOSED) | ||
| 14 | TEMP ACTUATOR PS (COLD) | 4 | DEF ACTUATOR (OPEN) | ||
| 15 | TEMP ACTUATOR PS (HOT) | 5 | DEF ACT''R F/B | ||
| 16 | TEMP ACT''R PS F/B | 6 | HUMIDITY (PWM) | ||
| 17 | C_CAN HIGH | 7 | - | ||
| 18 | C_CAN LOW | 8 | IGN2 | ||
| 19 | DELAY (+) | 9 | GROUND | ||
| 20 | ILL - (REO) | 10 | - | ||
| 21 | ION SIGNAL | 11 | BLOWER MOTOR (+) | ||
| 22 | CLEAN SIGNAL | 12 | PT (GATE) | ||
| 23 | IONIZER DIAGNOSIS | 13 | FET (DRAIN F/B) | ||
| 24 | MM_CAN HIGH | 14 | - | ||
| 25 | MM_CAN LOW | 15 | IGN1 | ||
| 26 | AMBIENT SENSOR (+) | 16 | BATTERY | ||
| 27 | - | ||||
| 28 | EVAPORATOR SENSOR (+) | ||||
| 29 | ECV + | ||||
| 30 | ECV - (GROUND) |
Components (3)
[UVO TYPE]
| Connector | Pin No. | Function | Connector | Pin No. | Function |
| A | 1 | BATT + (TAIL) | A | 31 | PHOTO SENSOR (-) LEFT |
| 2 | SENSOR SUPPLY (+5 V) | 32 | PHOTO SENSOR (-) RIGHT | ||
| 3 | HAZARD SIGNAL | 33 | HTD | ||
| 4 | ACC | 34 | REAR FOG LAMP SWITCH | ||
| 5 | ACTUATOR MODE (VENT) | 35 | K-Line | ||
| 6 | ACTUATOR MODE (DEF) | 36 | - | ||
| 7 | ACTUATOR F/B MODE | 37 | PAB_IGN1 | ||
| 8 | ACTUATOR INTAKE (FRE) | 38 | PAB OFF SIGNAL | ||
| 9 | INTAKE ACTUATOR (REC) | 39 | SBR SIGNAL | ||
| 10 | INTAKE ACTUATOR F/B | 40 | SENSOR GROUND | ||
| 11 | TEMP ACTUATOR DR (COLD) | B | 1 | GROUND | |
| 12 | TEMP ACTUATOR DR (HOT) | 2 | - | ||
| 13 | TEMP ACT''R DR F/B | 3 | DEF ACTUATOR (CLOSED) | ||
| 14 | TEMP ACTUATOR PS (COLD) | 4 | DEF ACTUATOR (OPEN) | ||
| 15 | TEMP ACTUATOR PS (HOT) | 5 | DEF ACT''R F/B | ||
| 16 | TEMP ACT''R PS F/B | 6 | HUMIDITY (PWM) | ||
| 17 | C_CAN HIGH | 7 | - | ||
| 18 | C_CAN LOW | 8 | IGN2 | ||
| 19 | DELAY (+) | 9 | GROUND | ||
| 20 | ILL - (REO) | 10 | - | ||
| 21 | - | 11 | BLOWER MOTOR (+) | ||
| 22 | - | 12 | PT (GATE) | ||
| 23 | - | 13 | FET (DRAIN F/B) | ||
| 24 | - | 14 | - | ||
| 25 | - | 15 | IGN1 | ||
| 26 | AMBIENT SENSOR (+) | 16 | BATTERY | ||
| 27 | - | ||||
| 28 | EVAPORATOR SENSOR (+) | ||||
| 29 | ECV + | ||||
| 30 | ECV - (GROUND) |