Hybrid Control System
Specifications
In this manual: Hybrid Control System
~7min read
Specification
Hybrid Control System
Hybrid Power Control Unit (HPCU)
| Item | Specification |
| Operating Voltage (V) | 204 - 275.2 |
| Operating Frequency (Hz) | Max. 826 |
| LDC Output Voltage (V) [Auxiliary 12V Battery] | 12.8 - 15.1 |
| LDC Rated Power (kW) | 1.8 |
| Cooling Method | By water |
Brake Switch
▷ Type: ON/OFF Switch
| Item | Brake Pedal Release | Brake Pedal Depressed | |
| Switch 1 | Max. 0.5V | Battery Voltage | |
| Switch 2 | IG OFF | Max. 50mV | |
| IG ON | Battery Voltage | Max. 0.5V | |
| Item | Specification |
| Gap [mm (in)] | 1.0 - 2.0 (0.039 - 0.079) |
DC Fuse
| Item | Specification |
| Rated Current (A) | 30 |
| Installation position | Inside HPCU |
High Voltage Battery System
Battery Pack Assembly
[General Specification]
| Item | Specification | Remarks |
| Number of Cells | 16 Cells × 4 Modules [64 Cell] | 1 Cell = 3.75 V |
| Cell Voltage Range (V) | 2.5 - 4.2 | |
| Cell Voltage deviation (V) | 40 mV or less | |
| Type | LiPB (Lithium ion Polymer Battery), Pouch type |
|
| Rated Voltage (V) | 240 | Terminal voltage at 1C rated discharging, 55% SOC, 20 °C |
| Nominal Capacity (Ah) | 6.5 | [Battery initial performance, 20 °C] |
[Operating Specification]
| Item | Specification |
| Max. Discharging Power (kW) | Max. 42 [55% SOC] |
| Max. Charging Power (kW) | Max. (-) 32 [55% SOC] |
| Operating Voltage (V) | 160 - 275 [2.5V ≤ Cell Voltage ≤ 4.2V] |
| Operating Current (A) | (-) 250 - (+) 250 |
Power Relay Assembly (PRA)
| Item | Specification |
| Rated Voltage (V) | 240 |
| Rated Current (A) | 80 |
High Voltage Battery Control System
Safety Plug
| Item | Specification | |
| Rated Voltage (V) | 450 | |
| Rated Current (A) | 80 | |
| Fuse Rated Current (A) | 125 | |
| Fuse Melting Time | Rated Current × 110% | Min. 4 hr |
| Rated Current × 200% | 5 - 100 s | |
| Rated Current × 300% | 0.5 - 15 s | |
| Rated Current × 500% | Max. 1 s | |
Main Fuse
| Item | Specification | |
| Rated Current (A) | 450 | |
| Fuse Rated Current (A) | 125 | |
| Installation position | Inside safety plug | |
| Fuse Melting Time | Rated Current × 110% | Min. 4 hr |
| Rated Current × 200% | 5 - 100 s | |
| Rated Current × 300% | 0.5 - 15 s | |
| Rated Current × 500% | Max. 1 s | |
Main Relay (+)/ (-)
| Item | Specification | |
| Contact | Rated Voltage (V) | 450 |
| Rated Current (A) | 80 | |
| Coil | Operating Voltage (V) | 12 |
| Resistance (Ω) | 29.7 - 36.3[20 °C] | |
Pre-Charge Relay
| Item | Specification | |
| Contact | Rated Voltage (V) | 450 |
| Rated Current (A) | 20 | |
| Coil | Operating Voltage (V) | 12 |
| Resistance (Ω) | 57 - 63 [20 °C] | |
Pre-Charge Resistor
| Item | Specification |
| Resistance (Ω) | 40 [20 °C] |
| Rated power (W) | 40 |
Battery Current Sensor
| Item | Output Voltage (V) | |
| Max. Current (A) | -300 (Charge) | 0.5 |
| 0 | 2.5 | |
| +300 (Discharge) | 4.5 | |
| Rated Current (A) | -80 (Charge) | 0.5 |
| 0 | 2.5 | |
| +80 (Discharge) | 4.5 | |
Battery Temperature & Air Inlet Temperature Sensor
[Air Inlet]
| Temperature | Resistance (kΩ) | |
| °C | °F | |
| -50 | -58 | 314.9 - 344.6 |
| -40 | -40 | 181.1 - 196.0 |
| -30 | -22 | 107.5 - 115.2 |
| -20 | -4 | 65.82 - 69.77 |
| -10 | 14 | 41.43 - 43.52 |
| 0 | 32 | 26.74 - 27.83 |
| 10 | 50 | 17.67 - 18.25 |
| 20 | 68 | 11.94 - 12.24 |
| 30 | 86 | 8.214 - 8.411 |
| 40 | 104 | 5.738 - 5.918 |
| 50 | 122 | 4.082 - 4.239 |
| 60 | 140 | 2.954 - 3.087 |
| 70 | 158 | 2.172 - 2.284 |
| 80 | 176 | 1.621 - 1.715 |
| 90 | 194 | 1.227 - 1.305 |
| 100 | 212 | 0.941 - 1.006 |
| 110 | 230 | 0.731 - 0.785 |

[Battery Temperature Sensor (Side of cell)]
| Temperature | Resistance (kΩ) | |
| °C | °F | |
| -50 | -58 | 351.1 - 385.0 |
| -40 | -40 | 196.6 - 213.1 |
| -30 | -22 | 114.4 - 122.7 |
| -20 | -4 | 68.94 - 73.15 |
| -10 | 14 | 42.59 - 44.76 |
| 0 | 32 | 27.14 - 28.27 |
| 10 | 50 | 17.78 - 18.36 |
| 20 | 68 | 11.96 - 12.25 |
| 30 | 86 | 8.202 - 8.399 |
| 40 | 104 | 5.721 - 5.901 |
| 50 | 122 | 4.069 - 4.226 |
| 60 | 140 | 2.945 - 3.078 |
| 70 | 158 | 2.169 - 2.280 |
| 80 | 176 | 1.622 - 1.715 |
| 90 | 194 | 1.228 - 1.306 |

High Voltage Battery Cooling System
Cooling Fan
Current
| Item | Specification |
| Motor max current (A) | Below. 3.8 |
Duty
| Duty (%) | Fan Speed (rpm) |
| 10 | 500 |
| 20 | 1,000 |
| 30 | 1,300 |
| 40 | 1,600 |
| 50 | 1,900 |
| 60 | 2,200 |
| 70 | 2,500 |
| 80 | 2,800 |
| 90 | 3,100 |
| 95 | 3,850 |
Low Voltage DC/DC Converter (LDC)
Low Voltage DC/DC Converter (LDC) [Inside HPCU]
| Item | Specification |
| Input Voltage (V) | 204 - 275.2 |
| Operating Frequency (Hz) | Max. 826 |
| Output Voltage (V) [Auxiliary 12V Battery] | 12.8 - 15.1 |
| LDC Rated Power (kW) | 1.8 |
| Cooling Method | By water |
Tightening Torques
Hybrid Control System
| Item | kgf·m | N·m | lb·ft |
| Low Voltage DC/DC Converter (LDC) power output cable mounting bolt | 1.1 - 1.4 | 10.8 - 13.7 | 7.9 - 10.1 |
| Low Voltage DC/DC Converter (LDC) ground cable mounting bolt | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Reservoir mounting bolt | 0.4 - 0.6 | 3.9 - 5.9 | 2.9 - 4.3 |
| Hybrid Power Control Unit (HPCU) mounting bolt | 2.2 - 2.4 | 21.6 - 23.5 | 15.9 - 17.4 |
| Hybrid Power Control Unit (HPCU) Tray mounting bolt | 2.2 - 2.4 | 21.6 - 23.5 | 15.9 - 17.4 |
| DC Fuse [Inside HPCU] cover mounting bolt | 0.5 - 0.7 | 4.9 - 6.9 | 3.6 - 5.1 |
| DC Fuse [HPCU] mounting bolt | 0.95 - 1.05 | 9.3 - 10.3 | 6.9 - 7.6 |
High Voltage Battery System
| Item | kgf·m | N·m | lb·ft |
| Auxiliary 12V Battery wiring harness mounting nut | 0.8 ~ 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Safety plug cable mounting nut | 0.8 ~ 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| High voltage battery system assembly upper frame mounting bolt | 2.0 ~ 3.0 | 19.6 - 29.4 | 14.5 - 21.7 |
| High voltage battery system assembly upper frame mounting nut (M8) | 2.0 ~ 3.0 | 19.6 - 29.4 | 14.5 - 21.7 |
| High voltage battery system assembly upper frame mounting nut (M6) | 0.8 ~ 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| High voltage battery rear cover mounting bolt / nut | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| High voltage battery front cover mounting bolt / nut | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Power relay assembly mounting nut | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Power relay assembly mounting nut [High voltage battery bus bar ↔ Power relay assembly terminal side] | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
High Voltage Battery Control System
| Item | kgf·m | N·m | lb·ft |
| BMS ECU mounting nut | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Safety plug cable mounting nut [Frame] | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Safey plug cavle mounting bolt [Module] | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
High Voltage Battery Cooling System
| Item | kgf·m | N·m | lb·ft |
| Cooling fan mounting bolt / nut | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
Low Voltage DC/DC Converter (LDC)
| kgf·m | N·m | lb·ft | |
| LDC power output cable mounting nut | 1.1 - 1.4 | 10.8 - 13.7 | 7.9 - 10.1 |
| LDC ground (-) cable mounting bolt | 0.8 - 1.2 | 7.8 - 11.8 | 5.8 - 8.7 |
| Hybrid Power Control Unit (HPCU) mounting bolt | 2.2 - 2.4 | 21.6 - 23.5 | 15.9 - 17.4 |
Power Cable
| Item | kgf·m | N·m | lb·ft |
| Ground cable mounting bolt (M6) | 1.1 - 1.4 | 10.8 - 13.7 | 7.9 - 10.1 |
| Auxiliary 12V battery (+) cable mounting nut [Engine room fuse & relay box] | 1.1 - 1.4 | 10.8 - 13.7 | 7.9 - 10.1 |
| Power cable mounting nut [Invertor & Engine Room Box ↔ High Voltage Battery System] | 1.1 - 1.4 | 10.8 - 13.7 | 7.9 - 10.1 |