Additional service when replacing ECM
Description
When replacing ECM, this procedure must be performed.
Work Procedure
1.PRECONDITIONING• Connect a CONSULT-III • Connect a battery charger • Electric load switch is OFF • Wait for the engine to cool [engine coolant temperature < 60?°C (140?°F) and air temperature < 50?°C (122?°F)].
NOTE:
While the ECM is being programmed the cooling fan motors are triggered automatically.
>> GO TO 2.
2.SAVE ECM DATATurn ignition switch ON.
Perform ???SAVE DATA FOR CPU REPLC??? in WORK SUPPORT mode with CONSULT-III.
>> GO TO 3.
3.REPLACE ECMReplace ECM.
>> GO TO 4.
4.WRITE ECM DATA 1. Wait at least 30 seconds to turn ON the ignition switch. 2. Perform ???PRGRM REINITIALIZE??? in WORK SUPPORT mode with CONSULT-III. 3. Perform ???WRT DATA AFTR REPLC CPU??? in WORK SUPPORT mode with CONSULT-III.4. Perform initialization of NATS system and registration of all NATS ignition key IDs.
Refer to SEC-50, "ECM : Work Procedure" (With intelligent key system), SEC-190, "ECM : Work Procedure" (Without intelligent key system). 5. Turn ignition switch OFF, wait at least 30 seconds and then turn ON. 6. Select ???DATA MONITOR??? mode in ECM with CONSULT-III.7. Check that the ???CODE PROGRAM??? indication.
Which is displayed on CONSULT-III? YES >> GO TO 6.
NO >> GO TO 5.
5.WRITE ECM DATA1. Perform initialization of NATS system and registration of all NATS ignition key IDs.
Refer to SEC-50, "ECM : Work Procedure" (With intelligent key system), SEC-190, "ECM : Work Procedure" (Without intelligent key system). 2. Turn ignition switch OFF, wait at least 30 seconds and then turn ON. 3. Select ???DATA MONITOR??? mode in ECM with CONSULT-III.4. Check that the ???CODE PROGRAM??? indication.
Which is displayed on CONSULT-III? YES >> GO TO 6.
NO >> Repeat above steps.
6.PERFORM VIN REGISTRATION1. Start engine and warm it up to normal operating temperature.
NOTE:
The start-up phase may last up to 30 seconds.
4. Follow the instruction of CONSULT-III display.
NOTE:
After replace ECM, stored DTC may appear on other control unit. Clear the malfunction memory of these control unit.
>> END