Engine Control System MR16DDT
G sensor calibration
In this manual: Engine Control System MR16DDT
~1min read
Description
ECM stores calibration data (inherent characteristic value) of G sensor to provide accurate control. Therefore, it is required to perform calibration of G sensor after the following work is performed.
• Removal/installation or replacement of G sensor • Replacement of ECM
Work Procedure
1.PREPARATION BEFORE CALIBRATION PROCEDURE 1. Park the vehicle on a level surface.2. Adjust air pressure of all tires to the specified pressure. WT-9, "Tire Air Pressure".
>> GO TO 2.
2.PERFORM CALIBRATION
With CONSULT-III
1. Turn ignition switch ON.
CAUTION:Never start engine. 2. Select “Work Support” mode in “ENGINE. 3. Select “G SENSOR CALIBRATION”.
4. Touch “Start”.
CAUTION:Never swing the vehicle during “G sensor calibration
”.
Is “COMPLETED” displayed? YES >> END NO >> Perform steps 1 and 2 again.