Power Window Control System
None of the power windows can be operated using any switch
In this manual: Power Window Control System
~1min read
Diagnosis Procedure 1.CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit. Refer to the following.
• With Intelligent Key: Refer to BCS-87, "Diagnosis Procedure".• Without Intelligent Key: Refer to BCS-155, "Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUITCheck power window main switch power supply and ground circuit.
Refer to PWC-18, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the malfunctioning parts.
3.CONFIRM THE OPERATIONConfirm the operation again.
Is the result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
NO >> GO TO 1.
Was this page helpful?