Electrical & Power Control

Combination Switch System Symptoms

3steps
~18min
2/5difficulty
Done 0 of 3
Symptom Table
  1. Perform the data monitor of CONSULT to check for any malfunctioning item.

  2. Check the malfunction combinations.

    Malfunction item: ×

    Malfunction combinationData monitor item
    FR WIPER HIFR WIPER LOWFR WASHER SWFR WIPER INTINT VOLUMERR WIPER ONRR WIPER INTRR WASHER SWTURN SIGNAL RTURN SIGNAL LTAIL LAMP SWHI BEAM SWHEAD LAMP SW 1HEAD LAMP SW 2PASSING SWAUTO LIGHT SWFR FOG SW
    A × × × ×
    B × × × ×
    C × × × ×
    D × × × ×
    E × × ×
    F × × ×
    G × × × ×
    H × × ×
    I × × × ×
    J × × × ×
    K All Items
    L If only one item is detected or the item is not applicable to the combinations A to K
  3. Identify the malfunctioning part from the agreed combination and repair or replace the part.

    Malfunction combinationMalfunctioning partRepair or replace
    A Combination switch INPUT 1 circuit Inspect the combination switch input circuit applicable to the malfunctioning part. Refer to Diagnosis Procedure.
    B Combination switch INPUT 2 circuit
    C Combination switch INPUT 3 circuit
    D Combination switch INPUT 4 circuit
    E Combination switch INPUT 5 circuit
    F Combination switch OUTPUT 1 circuit Inspect the combination switch output circuit applicable to the malfunctioning part. Refer to Diagnosis Procedure.
    G Combination switch OUTPUT 2 circuit
    H Combination switch OUTPUT 3 circuit
    I Combination switch OUTPUT 4 circuit
    J Combination switch OUTPUT 5 circuit
    K BCM Replace BCM. Refer to Removal and Installation.
    L Combination switch Replace the combination switch. Refer to Removal and Installation.