Main Power Window and Door Lock/unlock Switch
CHECK POWER WINDOW SWITCH OUTPUT SIGNAL
CONSULT
Select “CDL LOCK SW ” or “CDL UNLOCK SW” in “Data Monitor” mode of “BCM(DOOR LOCK)”. Refer to CONSULT Function (BCM - DOOR LOCK).
| Monitor item | Condition | |
|---|---|---|
| CDL LOCK SW | LOCK | : ON |
| UNLOCK | : OFF | |
| CDL UNLOCK SW | LOCK | : OFF |
| UNLOCK | : ON | |
Is the inspection result normal?
YES>>Power window serial link is OK.
NO>>Refer to Diagnosis Procedure.
Main power window and door lock/unlock switch, power window and door lock/unlock switch RH and BCM transmit and receive the signal by power window serial link.
The signal mentioned below is transmitted from BCM to main power window and door lock/unlock switch and power window and door lock/unlock switch RH:
Keyless power window down signal
The signal mentioned below is transmitted from main power window and door lock/unlock switch to power window and door lock/unlock switch RH:
Front door window RH operation signal
Power window lock switch signal
Retained power operation signal
Power Window Serial Link Check
CHECK POWER WINDOW SWITCH OUTPUT SIGNAL
Remove key and close front door LH and RH.
Check signal between BCM connector and ground with oscilloscope when door lock and unlock switch (LH and RH) is turned to “LOCK” or “UNLOCK”.
Check that signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch (LH and RH) is turned to “LOCK” or “UNLOCK”.
(+) (–) Signal
(Reference value)BCM Connector Terminal M19 54 Ground 
Is the inspection result normal?
YES>>Power window serial link is OK.
NO>>GO TO 2.
CHECK POWER WINDOW SERIAL LINK CIRCUIT
Ignition switch OFF.
Disconnect BCM connector and main power window and door lock/unlock switch harness connector.
Check continuity between BCM connector and main power window and door lock/unlock switch connector.
BCM Main power window and door lock/unlock switch Continuity Connector Terminal Connector Terminal M19 54 D7 11 Yes Check continuity between BCM connector and ground.
BCM Ground Continuity Connector Terminal M19 54 No
Is the inspection result normal?
YES>>Replace main power window and door lock/unlock switch. Refer to Removal and Installation.
NO>>Repair or replace harness or connectors.