S Terminal Circuit
Remove fuel pump fuse.
Crank or start the engine (where possible) until the fuel pressure is released.
CHECK STARTER MOTOR MAGNETIC SWITCH CIRCUIT
Ignition switch OFF.
Disconnect starter motor connector.
Shift transmission into P (Park) or N (Neutral).
Check voltage between starter motor connector and ground with the ignition switch in START.
(+) (—) Condition Voltage
(Approx.)Starter motor Connector Terminal F28 S Ground Ignition switch in START position Battery voltage
Is the inspection result normal?
YES>>Magnetic switch circuit is OK. Further inspection is necessary. Refer to Work Flow (With 165-DSS-5000P), or Work Flow (Without 165-DSS-5000P).
NO>>GO TO 2.
CHECK CONNECTOR
Ignition switch OFF.
Check the IPDM E/R connector F17 and starter motor connector F28 for damage, bent pins and loose connections.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair the terminal and connector.
CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Disconnect IPDM E/R connector and starter motor connector.
Check continuity between starter motor connector and IPDM E/R connector.
Starter motor IPDM E/R Continuity Connector Terminal Connector Terminal F28 S F17 51 Yes Check continuity between starter motor connector and ground.
Starter motor — Continuity Connector Terminal F28 S Ground No
Is the inspection result normal?
YES>>Further inspection is necessary. Refer to Work Flow (With 165-DSS-5000P), or Work Flow (Without 165-DSS-5000P).
NO>>Repair the harness.