Ventilation, Heater & Air Conditioner

System Setting

~3min read
Temperature Setting Trimmer (Front)

DESCRIPTION

If the temperature felt by the customer is different from the front air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.

HOW TO SET

CONSULT

Select “TEMP SET CORRECT” in “Work support” mode of “HVAC”.

Work support itemsDisplay (°C)Display (°F)
TEMP SET CORRECT 3.0 6
2.5 5
2.0 4
1.5 3
1.0 2
0.5 1
0 (initial status) 0 (initial status)
−0.5 −1
−1.0 −2
−1.5 −3
−2.0 −4
−2.5 −5
−3.0 −6
Foot Position Setting Trimmer

DESCRIPTION

In FOOT mode, the air blowing to DEF can change ON/OFF.

HOW TO SET

CONSULT

Select “BLOW SET” in “Work support” mode of “HVAC”.

Work support itemsDisplayDefroster door position
Auto controlManual control
BLOW SET Mode1 OPEN CLOSE
Mode2 (initial status) OPEN OPEN
Mode3 CLOSE OPEN
Mode4 CLOSE CLOSE
Inlet Port Memory Function (FRE)

DESCRIPTION

  • If ignition switch OFF while the intake switch is set to OFF (fresh air intake), “Perform the memory” or “Do not perform the memory” of intake switch OFF (fresh air intake) condition can be selected.

  • If “Perform the memory” was set, the intake switch will be OFF (fresh air intake) when ignition switch ON again.

  • If “Do not perform the memory” was set, the air inlets will be controlled automatically when ignition switch ON again.

HOW TO SET

CONSULT

Select “FRE MEMORY SET” in “Work support” mode of “HVAC”.

Work support itemsDisplaySetting
FRE MEMORY SET WITHOUT Perform the memory of manual FRE
WITH (initial status) Do not perform the memory of manual FRE (auto control)
Inlet Port Memory Function (REC)

DESCRIPTION

  • If ignition switch OFF while the intake switch is set to ON (recirculation), “Perform the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be selected.

  • If “Perform the memory” was set, the intake switch will be ON (recirculation) when ignition switch ON again.

  • If “Do not perform the memory” was set, the air inlets will be controlled automatically when ignition switch ON again.

HOW TO SET

CONSULT

Select “REC MEMORY SET” in “Work support” mode of “HVAC”.

Work support itemsDisplaySetting
REC MEMORY SET WITHOUT (initial status) Perform the memory of manual REC
WITH Do not perform the memory of manual REC (auto control)
Target Evaporator Temp Upper Limit

DESCRIPTION

Set the target evaporator temperature upper limit.

HOW TO SET

CONSULT

Select “TARGET EVAPORATOR TEMP UPPER LIMIT SETTING” in “Work support” mode of “HVAC”.

Work support itemsDisplay
TARGET EVAPORATOR TEMP UPPER LIMIT SETTING Initial Setting
Low
Middle
High