Generator Inverter Actuator Stuck Closed (P0A7A73)
DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC is stored when a short is detected in the inverter with converter assembly (generator inverter) or the hybrid vehicle transaxle assembly (generator (MG1)). The cause of this malfunction may be one of the following:
Internal inverter malfunction- Generator inverter internal circuit malfunction
- Open or short circuit
- Damage from iron particles or other foreign objects
DESCRIPTION
For a description of the inverter.
Click here ![]()
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Note |
|---|---|---|---|---|---|---|
P0A7A73 |
Generator Inverter Actuator Stuck Closed |
Current flow to any phase of the generator (MG1) exceeds the threshold after the generator inverter is shut down due to a DTC indicating a generator inverter malfunction (overheating, overcurrent or circuit malfunction) being stored. (1 trip detection logic) |
|
Comes on |
Master Warning: Comes on |
SAE Code: P0A7A |
MONITOR DESCRIPTION
The motor generator control ECU monitors the generator inverter electric current. If the current exceeds the threshold for a specified period of time, the motor generator control ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0A7A (INF P0A7A73): GFIV detection (Short circuit malfunction) |
Required sensors/components |
Generator inverter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0A7A (INF P0A7A73) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
.gif)
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
.gif)
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the ignition switch off and wait for 2 minutes or more.
- Turn the ignition switch to ON and wait for 5 seconds or more. [*1]
- Turn the ignition switch to ON (READY) and wait for 5 seconds or more. [*2]
HINT:
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
- Drive the vehicle for approximately 10 minutes mainly using the engine. [*3]
NOTICE:
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with ignition switch ON (READY) after repairs have been performed.
HINT:
[*1] to [*3]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here ![]()
CAUTION:
Refer to the precautions before inspecting high voltage circuit.
Click here ![]()
NOTICE:
- After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click here
.gif)
- When disconnecting and reconnecting the auxiliary battery.
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click here
.gif)
- DTC P0A7A73 is stored after DTC P0A7A9E and/or P1C5F19 is stored. After troubleshooting and repairing the malfunction which caused DTC P0A7A73 to be stored, be sure to troubleshoot the other DTCs.
- Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the inverter with converter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the inverter with converter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.
- After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 40 km/h for 1 minute and check that DTC P0A92000 is not output. If DTC P0A92000 is output, replace the hybrid vehicle transaxle assembly.
HINT:
- P0A7A73 may be output as a result of the malfunctions indicated by the DTCs in table below.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Malfunction Content | Relevant DTC |
|
|---|---|---|
Insulation malfunction |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
|
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
|
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
|
P1C8049 |
Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure |
|
PROCEDURE
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1))
Click here ![]()
| NG | GO TO STEP 3 |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Click here ![]()
| NEXT | GO TO STEP 12 |
CHECK MOTOR CABLE (FOR MG1)
Click here ![]()
| NG | GO TO STEP 6 |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
Click here ![]()
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Click here ![]()
| NEXT | GO TO STEP 12 |
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1))
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the motor cable from the hybrid vehicle transaxle assembly.
(c) Check the generator (MG1) for an interphase short using a milliohmmeter. (1) Using a milliohmmeter, measure the resistance according to the value(s) in the table below. HINT: If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle has been stopped. Standard Resistance:
HINT: To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20 °C.
The calculation is based on the following:
|
|
(d) Check the difference in measured resistance values according to the table below.
Standard:
Inspection Item | Specified Condition |
|---|---|
[*1] - [*2] |
-1.1 to 0.9 mΩ |
[*2] - [*3] |
-1.2 to 0.8 mΩ |
[*3] - [*1] |
-0.7 to 1.3 mΩ |
(e) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
Y2-4 (W) - Body ground and shield ground |
Ignition switch off |
100 MΩ or higher |
Y2-5 (U) - Body ground and shield ground |
Ignition switch off |
100 MΩ or higher |
Y2-6 (V) - Body ground and shield ground |
Ignition switch off |
100 MΩ or higher |
(f) Connect the motor cable.
| NG | GO TO STEP 9 |
|
REPLACE MOTOR CABLE
Click here ![]()
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Click here ![]()
| NEXT | GO TO STEP 12 |
REPLACE MOTOR CABLE
Click here ![]()
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
Click here ![]()
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Click here ![]()
|
CHECK DTC OUTPUT (MOTOR GENERATOR)
(a) Check the other DTCs that were output together with DTC P0A7A73.
Powertrain > Motor Generator > Trouble CodesRelevant DTC |
|
|---|---|
P0A7A9E |
Generator Inverter Stuck On |
P1C5F19 |
Generator Inverter Circuit Current Above Threshold |
NOTICE:
DTC P0A7A73 is stored after DTC P0A7A9E and/or P1C5F19 is stored. After troubleshooting and repairing the malfunction which caused DTC P0A7A73 to be stored, be sure to troubleshoot the other DTCs.
| NEXT | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |