Engine & Hybrid System

Inspection

~1min read

INSPECTION

PROCEDURE

1. INSPECT KNOCK CONTROL SENSOR

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

25 °C

120 to 280 kΩ

If the result is not as specified, replace the knock control sensor.

*a

Component without harness connected

(Knock Control Sensor)