Sensor Frozen Indication (Dirty or Frozen)
DESCRIPTION
When the ultrasonic sensor is dirty or frozen, "Parking Assist Unavailable Please Clean Parking Assist Sensor" is displayed on the multi-information display in the combination meter assembly.
PROCEDURE
CHECK FOR DTC
(a) Clear the DTCs.
Body Electrical > Clearance Warning > Clear DTCs(b) Check for DTCs.
Body Electrical > Clearance Warning > Trouble CodesResult | Proceed to |
|---|---|
DTCs are not output |
A |
DTC is output |
B |
| B | GO TO DIAGNOSTIC TROUBLE CODE CHART |
|
READ VALUE USING GTS
(a) According to the display on the GTS, read the Data List.
Body Electrical > Clearance Warning > Data ListTester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20CB is output if YES |
Tester Display |
|---|
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Result | Proceed to |
|---|---|
Sensor frozen history displays "YES" |
A |
Sensor frozen history displays "NO" |
B |
| B | GO TO STEP 4 |
|
CLEAN ULTRASONIC SENSORS
(a) Clean the ultrasonic sensor from dirty or frozen.
|
CLEAR DTC
(a) Clear the DTCs.
Body Electrical > Clearance Warning > Clear DTCs
|
READ VALUE USING GTS
(a) According to the display on the GTS, read the Data List.
Body Electrical > Clearance Warning > Data ListTester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C4 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C5 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C6 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C7 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C8 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20C9 is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20CA is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open |
Open circuit status of the ultrasonic sensor |
No or Yes |
NO: No sensor open circuit Yes: Sensor open circuit |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt |
Frozen/dirty status of the ultrasonic sensor |
No or Yes |
NO: Sensor not frozen/dirty Yes: Sensor frozen/dirty |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Foreign material fixing status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter not stuck on sensor Yes: Foreign matter stuck on sensor |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Foreign material fixing (curl up) status of the ultrasonic sensor |
No or Yes |
NO: Foreign matter (curl up) not stuck on sensor Yes: Foreign matter (curl up) stuck on sensor |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction |
Parameter malfunction status of the ultrasonic sensor |
No or Yes |
NO: No sensor parameter malfunction Yes: Sensor parameter malfunction |
RoB X20CB is output if YES |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Continuous flowing water status of the ultrasonic sensor |
No or Yes |
NO: No sensor continuous flowing water Yes: Sensor continuous flowing water |
RoB X20CB is output if YES |
Tester Display |
|---|
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction |
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously |
Result | Proceed to |
|---|---|
Sensor frozen history displays "NO" |
A |
Sensor frozen history displays "YES" |
B |
| A | END |
| B | REPLACE ULTRASONIC SENSOR for Front Click here for Rear Click here |