Diagnostics
Entire combination meter does not operate
In this manual: Diagnostics
11steps
~66min
3/5difficulty
Done 0 of 11
Wiring diagram

Inspection procedere 1 Check fuse


- Check that continuity exists of dome fuse.
- check that continuity exists of gauge fuse.
- check that continuity exists of am1 fuse.



- Check continuity.
- Disconnect the ”c9” connector from combination meter assy.
- Check continuity between terminal c9–2 of combination meter assy connector and body ground.
Ok: continuity exists

- Check voltage.
- Disconnect the ”c9” connector from combination meter assy.
- Measure voltage between terminal c9–5 of combination meter assy connector and body ground.
Voltage: 10 – 14 v
- turn the ignition switch to on.
- Measure voltage between terminal c9–4 of combination meter assy connector and body ground.
Voltage: 10 – 14 v