Cooling

Inspection

~1min read

1. INSPECT RELAY (Marking: FAN NO. 1, FAN NO. 3)

INSPECT RELAY (Marking: FAN NO. 1, FAN NO. 3)

(a) Check the resistance of the relay.

Standard:

INSPECT RELAY (Marking: FAN NO. 1, FAN NO. 3)

If the result is not as specified, replace the relay.

2. INSPECT RELAY (Marking: FAN NO. 2)

INSPECT RELAY (Marking: FAN NO. 2)

(a) Check the resistance of the relay.

Standard:

INSPECT RELAY (Marking: FAN NO. 2)

If the result is not as specified, replace the relay.

3. INSPECT ECT SWITCH (NO. 1)

INSPECT ECT SWITCH (NO. 1)

(a) Check the resistance.

Standard:

INSPECT ECT SWITCH (NO. 1)

If the result is not as specified, replace the switch.

NOTICE: When checking the ECT sensor in water, the terminals should be kept dry. After the check, dry the sensor.

4. INSPECT ECT SWITCH (NO. 2)

INSPECT ECT SWITCH (NO. 2)

(a) Check the resistance.

Standard:

INSPECT ECT SWITCH (NO. 2)

If the result is not as specified, replace the switch.