Air Conditioning

Ambient Temperature Sensor

~1min read
Components COMPONENTS ILLUSTRATION Inspection Inspection INSPECTION PROCEDURE

1. INSPECT AMBIENT TEMPERATURE SENSOR

(a) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

1 - 2

10 °C

3.00 to 3.73 kΩ

1 - 2

15 °C

2.45 to 2.88 kΩ

1 - 2

20 °C

1.95 to 2.30 kΩ

1 - 2

25 °C

1.60 to 1.80 kΩ

1 - 2

30 °C

1.28 to 1.47 kΩ

1 - 2

35 °C

1.00 to 1.22 kΩ

1 - 2

40 °C

0.80 to 1.00 kΩ

1 - 2

45 °C

0.65 to 0.85 kΩ

1 - 2

50 °C

0.50 to 0.70 kΩ

1 - 2

55 °C

0.44 to 0.60 kΩ

1 - 2

60 °C

0.36 to 0.50 kΩ

NOTICE:

  • Even slightly touching the sensor may change the resistance value. Be sure to hold the sensor connector.
  • When measuring, the sensor temperature must be the same as the ambient temperature.

HINT:

As the temperature increases, the resistance decreases (see the graph).

If the resistance is not as specified, replace the ambient temperature sensor.

Removal REMOVAL PROCEDURE

1. REMOVE RADIATOR GRILLE

2. REMOVE AMBIENT TEMPERATURE SENSOR 2. REMOVE AMBIENT TEMPERATURE SENSOR

2. REMOVE AMBIENT TEMPERATURE SENSOR

(a) Disengage the harness clamp.

(a) Disengage the harness clamp.

(b) Disconnect the connector and remove the ambient temperature sensor.

Installation INSTALLATION PROCEDURE

1. INSTALL AMBIENT TEMPERATURE SENSOR

(a) Engage the harness clamp and install the ambient temperature sensor.

(a) Engage the harness clamp and install the ambient temperature sensor.

(b) Connect the connector.

2. INSTALL RADIATOR GRILLE

Blower Motor Controller Blower Motor Controller

Test yourself

A quick Toyota Tacoma quiz: every answer comes with an explanation and a link to the manual page.