Vehicle Interior
Inspection
INSPECTION
PROCEDURE
1. INSPECT COOLER (ROOM TEMPERATURE SENSOR) THERMISTOR
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
1 - 2 |
10 °C |
3.00 to 3.73 kΩ |
15 °C |
2.45 to 2.88 kΩ |
20 °C |
1.95 to 2.30 kΩ |
25 °C |
1.60 to 1.80 kΩ |
30 °C |
1.28 to 1.47 kΩ |
35 °C |
1.00 to 1.22 kΩ |
40 °C |
0.80 to 1.00 kΩ |
45 °C |
0.65 to 0.85 kΩ |
50 °C |
0.50 to 0.70 kΩ |
55 °C |
0.44 to 0.60 kΩ |
60 °C |
0.36 to 0.50 kΩ |
NOTICE:
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph). Text in Illustration
*a |
Component without harness connected
(Cooler (Room Temperature Sensor) Thermistor) |
*b |
Resistance (kΩ) |
*c |
Temperature |
If the result is not as specified, replace the cooler (room temperature sensor) thermistor. |
 |
|
Was this page helpful?