Engine, Hybrid System

Inspection

~1min read

INSPECTION

PROCEDURE

1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

HINT:

The valve opening temperature is stamped on the water inlet with thermostat.

(a) Immerse the water inlet with thermostat in water and gradually heat the water.

(b) Check the valve opening temperature.

Standard valve opening temperature:

80 to 84 °C

If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.

(c) Check the valve lift.

Standard valve lift:

10 mm (0.394 in.) or more at 95 °C

If the valve lift is not as specified, replace the water inlet sub-assembly with thermostat.

(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77 °C).

If it is not fully closed, replace the water inlet sub-assembly with thermostat.