Vehicle Interior
Terminals Of Ecu
TERMINALS OF ECU
1. AIR CONDITIONING AMPLIFIER
(a) Measure the voltage and resistance according to the value(s) in the table below.
Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
J106-9 (SVDB) - Body ground |
R - Body ground |
Output climate control signal (Driver side) |
Ignition switch ON
Seat heater switch LH on |
Pulse generation
(see waveform) |
J106-10 (SVPB) - Body ground |
BE - Body ground |
Output climate control signal (Front passenger side) |
Ignition switch ON
Seat heater switch RH on |
Pulse generation
(see waveform) |
(1) Using an oscilloscope, check waveform. Measurement Condition
Item | Content |
Terminal No. (Symbol) |
J106-9 (SVDB) - Body ground
J106-10 (SVPB) - Body ground |
Tool Setting |
2 V/DIV., 500 μsec/DIV. |
Condition |
Ignition switch ON
Seat heater switch on |
2. AIR CONDITIONING CONTROL ASSEMBLY (See page ) |
Was this page helpful?