1ar-fe Fuel
Inspection
In this manual: 1ar-fe Fuel
~1min read
INSPECTION PROCEDURE
1. INSPECT FUEL PUMP ASSEMBLY WITH FILTER
(a) Inspect fuel pump resistance.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
1 - 2 |
20 °C |
0.2 to 3.0 Ω |
If the result is not as specified, replace the fuel pump.
(b) Inspect fuel pump operation.
(1) Connect a battery positive (+) lead to terminal 2 of the connector, and a negative (-) lead to terminal 1. Check that the fuel pump operates.
NOTICE:
- These tests must be performed within 10 seconds to prevent the coil from burning out.
- Keep the fuel pump as far away from the battery as possible.
- Always switch the voltage on and off on the battery side, not the fuel pump side.