Air conditioning system with refrigerant R134a
Testing equipment and tools
In this manual: Air conditioning system with refrigerant R134a
~3min read
List of test equipment, tools and materials
Note This list is an overview of the test equipment, tools and materials necessary for professional repairs to the refrigerant circuit.
|
Tools and materials available from distribution centre or importer |
| Overview | page |
| Air conditioner service station -VAS 6007A-; for other air conditioner service stations refer to → V.A.G equipment catalogue | → Fig. |
| Leak detector -V.A.G 1796- | → Fig. |
| Leak detecting system -VAS 6196- | → Fig. |
| Leak detection additive -VAS 6196/1- | not illustrated |
| Leak detecting system -VAS 6201- or later model | → Fig. |
| Air conditioner service station -VAS 6380- with purging device or air conditioner service station with purging device -VAS 6337- (latest available air conditioner service stations → V.A.G workshop equipment catalogue). With integrated program for purging refrigerant circuit using refrigerant R134a. | not illustrated |
| Purging device for refrigerant circuits -VAS 6337/1-, (other available refrigerant circuit purging devices → V.A.G workshop equipment catalogue. For purging refrigerant circuit using refrigerant R134a. May also be used on older air conditioner service stations (purging procedure must then be carried out manually) with a reservoir volume of at least 10 kg refrigerant R134a. | → Fig. |
| Purging device for refrigerant circuits -VAS 6336/1-, (other available refrigerant circuit purging devices → V.A.G workshop equipment catalogue. For purging refrigerant circuit using refrigerant R134a. May also be used on older air conditioner service stations (purging procedure must then be carried out manually) with a reservoir volume of at least 10 kg refrigerant R134a. | → Fig. |
| Adapter case VW/Audi passenger vehicle set -VAS 6338/1- for refrigerant circuits with refrigerant R134a. For connection of air conditioner service station to refrigerant circuit and to bridge certain components during purging with refrigerant R134a or blowing through with compressed air or nitrogen. | not illustrated |
| Adapter case commercial vehicle set -VAS 6338/50- for refrigerant circuits with refrigerant R134a. For connection of air conditioner service station to refrigerant circuit and to bridge certain components during purging or blowing through. | not illustrated |
Ultrasonic air conditioner cleaning unit -VAS 6189A- To remove unpleasant odours originating from air conditioning system. |
not illustrated |
Suction feed spray-gun -V.A.G 1538- V.A.G 1538/5, probe for evaporator cleaning, shortV.A.G 1538/6, probe for evaporator cleaning, longV.A.G 1538/7, probe for evaporator cleaning, 700 mm (CV)Cleaner D 600 100 A1Cleaning solution for evaporator D 600 100 A2To remove unpleasant odours from evaporator |
not illustrated |
Release tools case -VAS 6127- To open refrigerant pipes. |
→ Fig. |
Release tools -VAS 6127/1-3- To open refrigerant pipes. |
→ Fig. |
Counterhold -V.A.G 1616- For coupling plate (air conditioner compressor made by “Sanden”). |
→ Fig. |
| Puller -V.A.G 1616/1- for magnetic clutch (Sanden air conditioner compressor). | → Fig. |
| Magnetic clutch puller -V.A.G 1719- (Zexel air conditioner compressor). | → Fig. |
| Adapter set for refrigerant circuit -V.A.G 1785/1-10- R134a. | → Fig. |
| Combination fine filter unit for compressed air systems; oil, dirt and water separator as used for paint gun systems → Workshop equipment catalogue. | not illustrated |
| O-ring → Parts catalogue. | not illustrated |
| Refrigerant oil → Parts catalogue. | not illustrated |
| Socket insert -T10364- for valves of service connections on HP/LP side of refrigerant circuit. | → Fig. |
Test yourself
A quick Volkswagen Golf quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?
Note This list is an overview of the test equipment, tools and materials necessary for professional repairs to the refrigerant circuit.
Caution Non-authorised tools or materials (e.g. leak inhibitor additive) may cause damage or adversely influence the system.