Air conditioning system with refrigerant R134a
Tools and materials commercially available
In this manual: Air conditioning system with refrigerant R134a
~5min read
|
| Overview | page |
| Fin comb | → Fig. |
| Charging hoses 5/8"-18 UNF with valve opener | → Fig. |
| Connector piece for pressure bottles for refrigerant and sealing ring with quick-release coupling or threaded connector 5/8"-18 UNF | → Fig. |
| Valve caps 5/8" -18 UNF | → Fig. |
| Manifold gauge with pressure limiter for nitrogen | → Fig. |
| Quick-release coupling adapter for service connections, 2 included in items supplied with air conditioner service station | → Fig. |
| Open ring spanners of widths matching those of the threaded connections on the refrigerant pipes. | not illustrated |
| Valve opener for charging hoses | not illustrated |
| Connection nipple for tapered seal 5/8"-18 UNF | not illustrated |
| Compressed air gun with rubber nozzle | not illustrated |
| Hand shut-off valve 5/8" - 18 UNF | not illustrated |
| Recycling bottle for refrigerant R134a | not illustrated |
| Digital thermometer | not illustrated |
| Protective gloves | not illustrated |
| Protective goggles | not illustrated |
| Refrigerant R134a with pressure bottle (contents as required) | not illustrated |
| Nitrogen in pressure bottle | not illustrated |
| Strap wrench (oil filter) as counterhold for poly V-belt pulley | not illustrated |
Tools to be made locally |
| Overview | page |
| Charging hose with connector to the workshop's compressed air system | → Fig. |
Tools and materials available from distribution centre or importer
|
Air conditioning service station -VAS 6007A- (and further service stations currently available) → Workshop equipmentThe procedures for testing, extracting (recycling), evacuating and charging should be carried out in accordance with the respective user's manual. The installed filter and dryer must be renewed at the latest at the end of the period of use specified in the operating instructions and every time that the station is emptied (keep replacement filter on hand. they can be ordered from the manufacturer of the device, see user's manual. Air conditioner service stations or purging devices approved by VW but not shown here may also be used.→ Workshop equipment Note This air conditioner service station incorporates the following common individual devices: charging cylinder, manifold gauge, vacuum pump, shut-off valves and charging hoses. This air conditioner service station includes one of each type of quick-release coupling (for high-pressure and low-pressure side service connections). |
![]() |
Purging device for refrigerant circuits -VAS 6337/1- from “Behr” or later model. Note
With filter -1- and two large cylindrical sight glassesThe filter in the purging device for refrigerant circuits should be changed after about 2 purging cycles (depending on the level of contamination from the purged refrigerant circuits). If a heavily contaminated refrigerant circuit is purged (the refrigerant oil from the refrigerant circuit is black and viscous or there are large amounts of shavings in the refrigerant circuit) renew filter after purging refrigerant circuit. |
![]() |
Purging device for refrigerant circuits -VAS 6336/1- from “Waeco” or later model. Note
With filter -1- and one sight glassThe filter in the purging device for refrigerant circuits should be changed after about 2 purging cycles (depending on the level of contamination from the purged refrigerant circuits). If a heavily contaminated refrigerant circuit is purged (the refrigerant oil from the refrigerant circuit is black and viscous or there are large amounts of shavings in the refrigerant circuit) renew filter after purging refrigerant circuit. |
![]() |
Leak detector -V.A.G 1796- |
![]() |
Leak detecting system -VAS 6196- |
![]() |
Leak detecting system VAS 6201 or later model |
![]() |
| Release tool -VAS 6127- case comprising release tool -VAS 6127/1-release tool -VAS 6127/2- and release tool -VAS 6127/3- | ![]() |
Release tool -VAS 6127/1-release tool -VAS 6127/2-Blue 1/2 inchBlack 5/8 inchRed 3/8 inchWhite 3/4 inch |
![]() |
Release tool -VAS 6127/3-Green NW 8 for high-pressure lineBlack NW 13 for low-pressure line |
![]() |
| Counterhold -V.A.G 1616- for clutch pulley (for “Sanden” air conditioner compressors) | ![]() |
| Puller -V.A.G 1616/1- for clutch pulley (for “Sanden” air conditioner compressors) | ![]() |
Magnetic clutch puller -V.A.G 1719- (for “Zexel” air conditioner compressors) |
![]() |
Adapter set for refrigerant circuit -V.A.G 1785/1-10-Adapter to clean refrigerant circuit (flushing with refrigerant R134a) → Chapter or blowing through with compressed air or nitrogen → Chapter
M 18x1.5 V.A.G 1785/1M 20x1.5 V.A.G 1785/2M 24x1.5 V.A.G 1785/3M 28x1.5 V.A.G 1785/4
M 18x1.5 V.A.G 1785/5M 20x1.5 V.A.G 1785/6M 24x1.5 V.A.G 1785/7 |
![]() |
M 28x1.5 V.A.G 1785/8 |
![]() |
Valve adapters
Note
There is a Schrader valve screwed into connection -A-.A valve opener must be fitted into the charging hose connection. |
![]() |
| Socket insert -T10364- for valves of service connections on HP/LP side of refrigerant circuit | ![]() |
Test yourself
A quick Volkswagen Golf quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?
Caution Non-authorised tools or materials (e.g. leak inhibitor additive) may cause damage or adversely influence the system.
Note This air conditioner service station incorporates the following common individual devices: charging cylinder, manifold gauge, vacuum pump, shut-off valves and charging hoses. This air conditioner service station includes one of each type of quick-release coupling (for high-pressure and low-pressure side service connections).