Refrrigerant R134a Servicing

Welding and Soldering on Refrigeration Systems

~1min read
Before performing welding or soldering work on vehicles near the air conditioning system components, extract the refrigerant and remove the residue by flushing with compressed air and nitrogen. The products of refrigerant decomposition due to the effect of heat are not only toxic, but may also have a highly corrosive effect on pipes and system components. They mainly take the form of hydrogen fluoride.

Pungent Odor

A pungent odor indicates that the products of decomposition mentioned above have already formed. Avoid inhaling these substances under all circumstances, as otherwise the respiratory system, lungs and other organs could be damaged.

First Aid

Following contact with eyes or mucous membranes, immediately rinse with copious amounts of running water and consult an eye specialist. Following contact with the skin, immediately remove affected clothing and rinse skin with copious amounts of water. Following inhalation of highly concentrated refrigerant vapors, immediately take the affected person into the open air. Call a doctor. Administer oxygen in the event of breathing difficulties. If the affected person has difficulty breathing or cannot breathe, tip head back and perform mouth to mouth respiration.