  1. Disconnect the crankcase ventilation tube and vacuum tube from the Air Cleaner (ACL) outlet pipe.
  2. Loosen the 2 ACL outlet pipe clamps.
    • Remove the ACL outlet pipe.
    • To install, tighten to 3 N·m.
  3. To install, reverse the removal procedure.