Accessories

Aiming (Service Point Calibration)

6steps
~36min
2/5difficulty
Done 0 of 6

NOTE: Do the service calibration on a flat and straight road that has several lanes where you can drive at least 40 km/h. You must complete the aiming procedure within 10 minutes. The aiming procedure may fail if you take too long, if the weather is poor (rain, fog, or snow), or the white or yellow lines are not visible because of reflections from a wet road.

  1. Press the engine start/stop button to select the OFF mode.

  2. Connect the Honda Diagnostic System (HDS) to the data link connector (DLC) (A) located under the driver's side of the dashboard.

  3. Press the engine start/stop button to select the ON mode.

  4. Make sure the HDS communicates with the vehicle and the FCW/LDW camera unit. If it does not communicate, go to the DLC circuit troubleshooting.

  5. Start the engine. At this time, the FCW and LDW indicators come on.

  6. Follow the HDS onscreen instructions and confirm the results in the table below.