Body Electrical System

Description and Operation

15steps
~90min
4/5difficulty
Done 0 of 15

Description

The Smart Key System and Burglar Alarm are integrated with the Smart Key system. The Smart Key System allows locking and unlocking of the vehicle with the remote transmitter. When you press the LOCK button, all door locks are locked. When you press the UNLOCK button again, all doors are unlocked.

Function

The Smart Key DOOR LOCK/UNLOCK function and emergency operations are performed using the remote control.
  1. The Smart Key function is performed when the key is removed from the key cylinder in the switch.
  2. LOCK / UNLOCK and panic signals are received from the transmitter, and DOOR LOCK / UNLOCK and panic signals are output.
  3. Transmission range: 30 m or more outside the vehicle
  4. Transmitter Registration Procedure
    1. In registration mode, up to a maximum of 4 EA can be registered.
    2. When re-registering, data is registered anew after deleting the previous TX DATA.
      No. Stored code Code to change Changed code
      1 A C C (A deleted)
      2 A, B, C, D E E (A, B, C, D deleted)
      3 A, B C, D, E C, D, E
      4 A, B C, C, D C
    3. For registration procedures using the Hi-scan tool, refer to "TRANSMITTER CODE REGISTRATION".
  5. Transmitter Signal and Receiver Specifications
    1. Transmission signal
      A. Transmit the corresponding transmission data (transmission frame) twice by pressing TX SW.
      B. If the TX LOCK switch and the UNLOCK switch are pressed simultaneously, only the LOCK signal is output.
  6. Anti-theft Control Data Flow
Transmitter (TX) Specification Anti-theft Function

Functions

  1. DISARM Condition 1
    Condition Description
    Initial Condition ALARM
    Event
    • IGN KEY ON within 30 seconds or ALT "L" = ON within 3 seconds.
    NOT SMK (Smart Key)
    • Any door open and TX UNLOCK
    • TX Rear door
    • TX Lock & Lock confirmation failed
    SMK:
    • Any door open and RKE CMD=UNLOCK / Passive Access Unlock=1
    • RKE_Liftgate=1 - TP (transponder) AUTH=1 / PIC AUTH=1
    • RKE CMD=LOCK / Passive Access Lock=1 and lock confirmation failed
    Mechanical key OPTION Enable:
    • Mechanical UNLOCK
    • Mechanical LOCK & Lock confirmation failed
    Action Status changes to DISARM state
    • Horn relay, hazard relay, starter interrupt relay OFF.
    • Unlock TX > Unlock relay for 0.5 sec. > Hazard relay ON (twice)

    T1: 0.5 s, T2: 0.5 s ± 0.1 s
    Condition 2
    Condition Description
    Initial Condition DISARM state & (IGN KEY OUT) and any door open
    Event Non-SMK:
    • Any door open and TX UNLOCK
    SMK:
    • Any door open and RKE CMD=UNLOCK / Passive Access Unlock=1 / RKE Rear Door = 1 / Rear door re-open = 1
    • AUTH TP=1 / AUTH PIC=1
    Action No change of state
    • TX UNLOCK, RKE CMD=UNLOCK, Passive Access Unlock=1 > Hazard relay ON/OFF for 0.5 s (twice)

    Condition 3
    Condition Description
    Initial Condition ARM WAIT state
    Event
    • Any door open or hood switch OPEN or liftgate switch OPEN
    • Any door open
    • Key Ignition switch
    SMK:
    TP AUTH=1 / PIC AUTH=1 / FOB=IN / P Rear Door
    Mechanical key OPTION Enable:
    Mechanical UNLOCK
    Action State changes to DISARM state

    Condition 4
    Condition Description
    Initial Condition AUTO LOCK TIMER 1 STATE
    Event
    • Any door open or hood switch OPEN or liftgate switch OPEN
    • Key Ignition Switch ON
    • AUTO LOCK & Lock confirmation error
    Specification non-SMK:
    • TX LOCK & Lock confirmation error
    Specification SMK:
    • RKE CMD=LOCK / Passive Access Lock=1 & Lock confirmation error
    • AUTH TP=1 / AUTH PIC=1
    Mechanical key OPTION Enable:
    • Mechanical LOCK and lock confirmation error
    Action State changes to DISARM state

    Condition 5
    Condition Description
    Initial Condition AUTO LOCK TIMER 2 STATE
    Event
    • Any door open
    • Key Ignition Switch ON
    • AUTO LOCK & Lock confirmation error
    Non-SMK:
    • TX LOCK & Lock confirmation error
    SMK:
    • RKE CMD=LOCK / Passive Access Lock=1 & Lock confirmation error
    • TP AUTH=1/ PIC AUTH=1 / FOB IN
    Mechanical key OPTION Enable:
    Mechanical LOCK and lock confirmation error
    Action State changes to DISARM state

    Condition 6
    Condition Description
    Initial Condition ALARM STATE
    Event
    • IGNITION KEY ON
    SMK:
    • AUTH TP=1 / AUTH PIC=1
    Mechanical key OPTION Enable:
    • Mechanical UNLOCK
    Action State changes to DISARM state

    Condition 7
    Condition Description
    Initial Condition REARM state
    Event Except Chinese specification:
    • IGNITION ON within 30 seconds or ALT "L" = ON for 3 seconds.
    Non-SMK:
    • TX LOCK & Lock confirmation error
    • TX Rear door
    SMK:
    • AUTH TP=1 / AUTH PIC=1
    • RKE CMD=LOCK / Passive Access Lock=1 and lock confirmation error
    • RKE Rear Door = 1
    Mechanical key OPTION Enable:
    • Mechanical UNLOCK
    • Mechanical LOCK and lock confirmation error
    Action State changes to DISARM state
    Starter interrupt relay OFF.

    Condition 8
    Condition Description
    Initial Condition PRE-ARM state
    • Key Ignition Switch ON
    • All inputs closed and any door open
    Non-SMK:
    • Any door open and TX UNLOCK
    SMK:
    • TP AUTH=1 / SMK AUTH=1 / FOB IN
    • Any door open and RKE CMD=UNLOCK / Passive Access Unlock=1
    Mechanical key OPTION Enable:
    • MECHANICAL UNLOCK
    Action Status changes to DISARM state
    • Hazard relay ON/OFF for 0.5 s (twice)

    Condition 9
    Condition Description
    Initial Condition AUTO LOCK TIMER 3 STATE
    Event
    • DRV or AST or RL or RR DOOR OPEN or HOOD OPEN or KEY ON
    Specification SMK:
    • TP AUTH=1 or SMK AUTH=1
    Mechanical key OPTION Enable:
    • Mechanical UNLOCK
    • Mechanical LOCK and lock confirmation error
    Action Record DISARM state
  2. HAND Condition 1
    Condition Description
    Initial Condition ARM state
    Event Non-SMK:
    • TX LOCK
    SMK:
    • RKE CMD=LOCK / Passive Access Lock=1
    Action No change of state
    Hazard 1 time (1 sec)

    Condition 2
    Condition Description
    Initial Condition ARM WAIT state
    Event
    • After ARM WAIT TIMER is completed
    Action State changes to ARM state
  3. ALARM Condition 1
    Condition Description
    Initial Condition ARM state
    Event Any door open or hood switch open
    Action State changes to ALARM state
    • Engine start prohibition ON
    • Horn relay ON once for 27 seconds (±2 seconds) and OFF twice for 10 seconds (±1 second).
    • Hazard also operated (during horn sounding)

    T1: 27 s (± 2 s), T2: 10 s (± 2 s), T3: 0.5 s ± 0.1 s Condition 2
    Condition Description
    Initial Condition REARM state
    Event Any door open or hood switch OPEN
    Action State changes to ALARM state
    Horn relay ON once for 27 seconds (±2 seconds) and OFF twice for 10 seconds (±1 second).
    Hazard also operated (during horn sounding)

  4. ARM WAIT state Condition 1
    Condition Description
    Initial Condition ARMWAIT state
    Event Non-SMK:
    • TX LOCK
    SMK:
    • RKE CMD = LOCK / Passive Access Lock = 1
    Action No change of state
    Hazard relay 1 time (1 sec)

    Condition 2
    Condition Description
    Initial Condition DISARM state, IGNITION OFF, all inputs closed
    Event Non-SMK:
    • TX lock and lock confirmed
    SMK:
    • RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
    Mechanical key OPTION Enable:
    • MECHANICAL LOCK and lock confirmed
    • DOOR LOCK state: Any door open > All doors closed
    Action
    • State changes to ARMWAIT state
    • Start ARMWAIT TIMER
    • Hazard relay 1 time (1 sec)

    Condition 3
    Condition Description
    Initial Condition ALARM state, all inputs closed, ignition key removed
    Event Non-SMK:
    • TX lock and lock confirmed
    SMK:
    • RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
    Mechanical key OPTION Enable:
    • MECHANICAL LOCK and lock confirmed
    Action
    • State changes to ARMWAIT state
    • Horn relay, starter interrupt relay = OFF.
    • Hazard relay 1 time (1 sec) (MECHANICAL LOCK: except)
    • Start PREPARE TIMER

    Condition 4
    Condition Description
    Initial Condition AUTO LOCK TIMER 1 STATE
    Event AUTO LOCK and lock confirmed
    Non-SMK:
    • TX lock and lock confirmed
    SMK:
    • RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
    Mechanical Key Option Enable:
    MECHANICAL LOCK and lock confirmed
    Action
    • State changes to ARMWAIT state
    • Hazard relay 1 time (1 sec)
    • Start PREPARE TIMER

    Condition 5
    Condition Description
    Initial Condition PRE-ARM state
    Event All doors closed and ALL doors = locked
    Action
    • State changes to ARMWAIT state
    • Hazard relay 1 time (1 sec)
    • Start PREPARE TIMER

    Condition 6
    Condition Description
    Initial Condition REARM state
    Event Non-SMK:
    TX LOCK and lock confirmed
    SMK:
    • RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
    Mechanical key OPTION Enable:
    • MECHANICAL LOCK and lock confirmed
    Action
    • State changes to ARMWAIT state
    • Hazard relay 1 time (1 sec) (MECHANICAL LOCK: except)
    • Starter Interrupt Relay OFF
    • Start PREPARE TIMER

    Condition 7
    Condition Description
    Initial Condition AUTOLOCK3 state
    Event Specification non-SMK:
    • TX LOCK and lock confirmed
    Specification SMK:
    • RKE CMD=LOCK or Passive Access Lock=1 & lock confirmed
    Mechanical key OPTION Enable:
    • Mechanical LOCK and lock confirmed
    Action Enter ARM WAIT state
    • Hazard relay ON once (1 sec). (Except Mechanical LOCK option)
    • Start ARMWAIT timer.

  5. REARM mode Condition 1
    Condition Description
    Initial Condition ALARM state
    Event All entries closed and ALARM pattern finished
    Action Transition to REARM state
  6. Autolocktimer1 mode Condition 1
    Condition Description
    Initial Condition ARM state
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER1 state.
    • Start AUTO LOCK TIMER1
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF)

    Condition 2
    Condition Description
    Initial Condition AUTO LOCK TIMER 1 STATE
    Event AUTO LOCK TIMER1 completed
    Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action State unchanged
    CASE 1: AUTO LOCK TIMER1 Done
    AUTO LOCK
    CASE 2: TX UNLOCK, RKE CMD=UNLOCK, Passive Access Unlock=1
    Hazard relay ON twice (0.5 s ON / 0.5 s OFF)
    Restart AUTO LOCK TIMER1.

    Condition 3
    Condition Description
    Initial Condition ARM WAIT state
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER1 state.
    • Start AUTO LOCK TIMER1
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).

    Condition 4
    Condition Description
    Initial Condition DISARM, all entries closed (DOORS, HOOD and LIFTGATE) and IGN KEY IN
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER1 state.
    • Start AUTO LOCK TIMER1
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).

    Condition 5
    Condition Description
    Initial Condition ALARM state and all entries closed
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER1 state.
    • Start AUTO LOCK TIMER1
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
    • Starter Interrupt Relay OFF / Horn Relay OFF

    Condition 6
    Condition Description
    Initial Condition REARM state
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action Transition to AUTO LOCK TIMER1 state.
    • Start AUTO LOCK TIMER1
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
    • Starter Interrupt Relay OFF
  7. Autolocktimer2 mode Condition 1
    Condition Description
    Initial Condition AUTO LOCK TIMER2 state
    Event AUTO LOCK TIMER2 completed
    Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action State unchanged
    CASE 1: AUTO LOCK TIMER2 completed
    AUTO LOCK
    CASE2: TX UNLOCK, RKE CMD=UNLOCK, Passive Access Unlock=1
    • Start AUTO LOCK TIMER2
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).

    Condition 2
    Condition Description
    Initial Condition DISARM state, IGN KEY OUT and ALL doors closed.
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER2 state.
    • Start AUTO LOCK TIMER2
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
    • Hood/Trunk status memo

    Condition 3
    Condition Description
    Initial Condition ALARM state & All doors closed & status (trunk or hood switch OPEN)
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER2 state.
    • Horn relay, starter interrupt relay = OFF.
    • Start AUTO LOCK TIMER2
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
    • Hood/Trunk status memo

    Condition 4
    Condition Description
    Initial Condition PREARM state, all doors closed and status (hood open)
    Event Non-SMK:
    TRANSMITTER UNLOCK
    SMK:
    RKE CMD=UNLOCK / Passive Access Unlock=1
    Action
    • Transition to AUTO LOCK TIMER2 state.
    • Start AUTO LOCK TIMER2
    • Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
    • Hood/Trunk status memo
  8. PREARM mode Condition 1
    Condition Description
    Initial Condition AUTO LOCK TIMER2 state
    Event AUTO LOCK and lock confirmed
    Non-SMK:
    TX LOCK and lock confirmed
    SMK:
    RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
    Mechanical Key Option Enable:
    MECHANICAL LOCK and lock confirmed
    Action Transition to PREARM state

    Condition 2
    Condition Description
    Initial Condition DISARM and IGN KEY IN state
    Event Non-SMK:
    • Any door open or hood switch in OPEN position or trunk switch in OPEN state and lock confirmed
    SMK:
    • Any door open or hood switch OPEN or trunk switch OPEN state RKE CMD=LOCK / Passive Access Lock=1 & lock confirmed
    Mechanical Key Option Enable:
    MECHANICAL LOCK and lock confirmed
    ALL DOOR LOCK state (any door open > all doors closed) and (trunk switch OPEN or hood switch OPEN)
    Action Transition to PREARM state

    Condition 3
    Condition Description
    Initial Condition ALARM & IGN KEY OUT state and (any door open or hood switch OPEN or trunk switch OPEN)
    Event Non-SMK:
    TX LOCK and lock confirmed
    SMK:
    RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
    Mechanical Key Option Enable:
    MECHANICAL LOCK and lock confirmed
    Action Transition to PREARM state
    Horn relay, hazard relay, starter interrupt relay > OFF

    Condition 4
    Condition Description
    Initial Condition AUTOLOCK3 state
    Event TIMER DISABLED
    LIFTGATE OPEN
    Action Enter PREARM state
  9. Autolock Time3 mode Condition 1
    Condition Description
    Initial Condition AUTOLOCK3 state
    Event Specification non-SMK:
    • TX LIFTGATE
    Specification SMK:
    • RKE LIFTGATE=1
    Action AUTOLOCK3 maintenance and
    • Hazard twice ON (0.5 s ON / 0.5 s OFF)

    Condition 2
    Condition Description
    Initial Condition ARM state
    Event Specification non-SMK:
    • TX LIFTGATE
    Specification SMK:
    • RKE LIFTGATE=1 or passive LIFTGATE
    Action Enter AUTOLOCK3 state and hazard relay twice (0.5 s ON / 0.5 s OFF)

    Condition 3
    Condition Description
    Initial Condition ARMWAIT state
    Event Specification non-SMK:
    • TX LIFTGATE
    Specification SMK:
    • RKE LIFTGATE=1
    Action Enter AUTOLOCK3 state and hazard relay twice (0.5 s ON / 0.5 s OFF)

Test yourself