The Smart Key System and Burglar Alarm are integrated with the Smart Key system. The Smart Key System allows locking and unlocking of the vehicle with the remote transmitter. When you press the LOCK button, all door locks are locked. When you press the UNLOCK button again, all doors are unlocked.
Function
The Smart Key DOOR LOCK/UNLOCK function and emergency operations are performed using the remote control.
The Smart Key function is performed when the key is removed from the key cylinder in the switch.
LOCK / UNLOCK and panic signals are received from the transmitter, and DOOR LOCK / UNLOCK and panic signals are output.
Transmission range: 30 m or more outside the vehicle
Transmitter Registration Procedure
In registration mode, up to a maximum of 4 EA can be registered.
When re-registering, data is registered anew after deleting the previous TX DATA.
No.
Stored code
Code to change
Changed code
1
A
C
C (A deleted)
2
A, B, C, D
E
E (A, B, C, D deleted)
3
A, B
C, D, E
C, D, E
4
A, B
C, C, D
C
For registration procedures using the Hi-scan tool, refer to "TRANSMITTER CODE REGISTRATION".
Transmitter Signal and Receiver Specifications
Transmission signal
A.
Transmit the corresponding transmission data (transmission frame) twice by pressing TX SW.
B.
If the TX LOCK switch and the UNLOCK switch are pressed simultaneously, only the LOCK signal is output.
Anti-theft Control Data Flow
Transmitter (TX) Specification Anti-theft Function
Functions
DISARM Condition 1
Condition
Description
Initial Condition
ALARM
Event
IGN KEY ON within 30 seconds or ALT "L" = ON within 3 seconds.
NOT SMK (Smart Key)
Any door open and TX UNLOCK
TX Rear door
TX Lock & Lock confirmation failed
SMK:
Any door open and RKE CMD=UNLOCK / Passive Access Unlock=1
Mechanical key OPTION Enable: Mechanical LOCK and lock confirmation error
Action
State changes to DISARM state
Condition 6
Condition
Description
Initial Condition
ALARM STATE
Event
IGNITION KEY ON
SMK:
AUTH TP=1 / AUTH PIC=1
Mechanical key OPTION Enable:
Mechanical UNLOCK
Action
State changes to DISARM state
Condition 7
Condition
Description
Initial Condition
REARM state
Event
Except Chinese specification:
IGNITION ON within 30 seconds or ALT "L" = ON for 3 seconds.
Non-SMK:
TX LOCK & Lock confirmation error
TX Rear door
SMK:
AUTH TP=1 / AUTH PIC=1
RKE CMD=LOCK / Passive Access Lock=1 and lock confirmation error
RKE Rear Door = 1
Mechanical key OPTION Enable:
Mechanical UNLOCK
Mechanical LOCK and lock confirmation error
Action
State changes to DISARM state Starter interrupt relay OFF.
Condition 8
Condition
Description
Initial Condition
PRE-ARM state
Key Ignition Switch ON
All inputs closed and any door open
Non-SMK:
Any door open and TX UNLOCK
SMK:
TP AUTH=1 / SMK AUTH=1 / FOB IN
Any door open and RKE CMD=UNLOCK / Passive Access Unlock=1
Mechanical key OPTION Enable:
MECHANICAL UNLOCK
Action
Status changes to DISARM state
Hazard relay ON/OFF for 0.5 s (twice)
Condition 9
Condition
Description
Initial Condition
AUTO LOCK TIMER 3 STATE
Event
DRV or AST or RL or RR DOOR OPEN or HOOD OPEN or KEY ON
Specification SMK:
TP AUTH=1 or SMK AUTH=1
Mechanical key OPTION Enable:
Mechanical UNLOCK
Mechanical LOCK and lock confirmation error
Action
Record DISARM state
HAND Condition 1
Condition
Description
Initial Condition
ARM state
Event
Non-SMK:
TX LOCK
SMK:
RKE CMD=LOCK / Passive Access Lock=1
Action
No change of state Hazard 1 time (1 sec)
Condition 2
Condition
Description
Initial Condition
ARM WAIT state
Event
After ARM WAIT TIMER is completed
Action
State changes to ARM state
ALARM Condition 1
Condition
Description
Initial Condition
ARM state
Event
Any door open or hood switch open
Action
State changes to ALARM state
Engine start prohibition ON
Horn relay ON once for 27 seconds (±2 seconds) and OFF twice for 10 seconds (±1 second).
Hazard also operated (during horn sounding)
T1: 27 s (± 2 s), T2: 10 s (± 2 s), T3: 0.5 s ± 0.1 s Condition 2
Condition
Description
Initial Condition
REARM state
Event
Any door open or hood switch OPEN
Action
State changes to ALARM state Horn relay ON once for 27 seconds (±2 seconds) and OFF twice for 10 seconds (±1 second). Hazard also operated (during horn sounding)
ARM WAIT state Condition 1
Condition
Description
Initial Condition
ARMWAIT state
Event
Non-SMK:
TX LOCK
SMK:
RKE CMD = LOCK / Passive Access Lock = 1
Action
No change of state Hazard relay 1 time (1 sec)
Condition 2
Condition
Description
Initial Condition
DISARM state, IGNITION OFF, all inputs closed
Event
Non-SMK:
TX lock and lock confirmed
SMK:
RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
Mechanical key OPTION Enable:
MECHANICAL LOCK and lock confirmed
DOOR LOCK state: Any door open > All doors closed
Action
State changes to ARMWAIT state
Start ARMWAIT TIMER
Hazard relay 1 time (1 sec)
Condition 3
Condition
Description
Initial Condition
ALARM state, all inputs closed, ignition key removed
Event
Non-SMK:
TX lock and lock confirmed
SMK:
RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
Mechanical key OPTION Enable:
MECHANICAL LOCK and lock confirmed
Action
State changes to ARMWAIT state
Horn relay, starter interrupt relay = OFF.
Hazard relay 1 time (1 sec) (MECHANICAL LOCK: except)
Start PREPARE TIMER
Condition 4
Condition
Description
Initial Condition
AUTO LOCK TIMER 1 STATE
Event
AUTO LOCK and lock confirmed
Non-SMK:
TX lock and lock confirmed
SMK:
RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
Mechanical Key Option Enable: MECHANICAL LOCK and lock confirmed
Action
State changes to ARMWAIT state
Hazard relay 1 time (1 sec)
Start PREPARE TIMER
Condition 5
Condition
Description
Initial Condition
PRE-ARM state
Event
All doors closed and ALL doors = locked
Action
State changes to ARMWAIT state
Hazard relay 1 time (1 sec)
Start PREPARE TIMER
Condition 6
Condition
Description
Initial Condition
REARM state
Event
Non-SMK: TX LOCK and lock confirmed
SMK:
RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
Mechanical key OPTION Enable:
MECHANICAL LOCK and lock confirmed
Action
State changes to ARMWAIT state
Hazard relay 1 time (1 sec) (MECHANICAL LOCK: except)
Starter Interrupt Relay OFF
Start PREPARE TIMER
Condition 7
Condition
Description
Initial Condition
AUTOLOCK3 state
Event
Specification non-SMK:
TX LOCK and lock confirmed
Specification SMK:
RKE CMD=LOCK or Passive Access Lock=1 & lock confirmed
Mechanical key OPTION Enable:
Mechanical LOCK and lock confirmed
Action
Enter ARM WAIT state
Hazard relay ON once (1 sec). (Except Mechanical LOCK option)
Start ARMWAIT timer.
REARM mode Condition 1
Condition
Description
Initial Condition
ALARM state
Event
All entries closed and ALARM pattern finished
Action
Transition to REARM state
Autolocktimer1 mode Condition 1
Condition
Description
Initial Condition
ARM state
Event
Non-SMK: TRANSMITTER UNLOCK
SMK: RKE CMD=UNLOCK / Passive Access Unlock=1
Action
Transition to AUTO LOCK TIMER1 state.
Start AUTO LOCK TIMER1
Hazard relay ON twice (0.5 s ON / 0.5 s OFF)
Condition 2
Condition
Description
Initial Condition
AUTO LOCK TIMER 1 STATE
Event
AUTO LOCK TIMER1 completed
Non-SMK: TRANSMITTER UNLOCK
SMK: RKE CMD=UNLOCK / Passive Access Unlock=1
Action
State unchanged
CASE 1: AUTO LOCK TIMER1 Done AUTO LOCK
CASE 2: TX UNLOCK, RKE CMD=UNLOCK, Passive Access Unlock=1 Hazard relay ON twice (0.5 s ON / 0.5 s OFF) Restart AUTO LOCK TIMER1.
Condition 3
Condition
Description
Initial Condition
ARM WAIT state
Event
Non-SMK: TRANSMITTER UNLOCK
SMK: RKE CMD=UNLOCK / Passive Access Unlock=1
Action
Transition to AUTO LOCK TIMER1 state.
Start AUTO LOCK TIMER1
Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
Condition 4
Condition
Description
Initial Condition
DISARM, all entries closed (DOORS, HOOD and LIFTGATE) and IGN KEY IN
ALARM state & All doors closed & status (trunk or hood switch OPEN)
Event
Non-SMK: TRANSMITTER UNLOCK
SMK: RKE CMD=UNLOCK / Passive Access Unlock=1
Action
Transition to AUTO LOCK TIMER2 state.
Horn relay, starter interrupt relay = OFF.
Start AUTO LOCK TIMER2
Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
Hood/Trunk status memo
Condition 4
Condition
Description
Initial Condition
PREARM state, all doors closed and status (hood open)
Event
Non-SMK: TRANSMITTER UNLOCK
SMK: RKE CMD=UNLOCK / Passive Access Unlock=1
Action
Transition to AUTO LOCK TIMER2 state.
Start AUTO LOCK TIMER2
Hazard relay ON twice (0.5 s ON / 0.5 s OFF).
Hood/Trunk status memo
PREARM mode Condition 1
Condition
Description
Initial Condition
AUTO LOCK TIMER2 state
Event
AUTO LOCK and lock confirmed
Non-SMK: TX LOCK and lock confirmed
SMK: RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
Mechanical Key Option Enable: MECHANICAL LOCK and lock confirmed
Action
Transition to PREARM state
Condition 2
Condition
Description
Initial Condition
DISARM and IGN KEY IN state
Event
Non-SMK:
Any door open or hood switch in OPEN position or trunk switch in OPEN state and lock confirmed
SMK:
Any door open or hood switch OPEN or trunk switch OPEN state RKE CMD=LOCK / Passive Access Lock=1 & lock confirmed
Mechanical Key Option Enable: MECHANICAL LOCK and lock confirmed ALL DOOR LOCK state (any door open > all doors closed) and (trunk switch OPEN or hood switch OPEN)
Action
Transition to PREARM state
Condition 3
Condition
Description
Initial Condition
ALARM & IGN KEY OUT state and (any door open or hood switch OPEN or trunk switch OPEN)
Event
Non-SMK: TX LOCK and lock confirmed
SMK: RKE CMD=LOCK / Passive Access Lock=1 and lock confirmed
Mechanical Key Option Enable: MECHANICAL LOCK and lock confirmed
Action
Transition to PREARM state Horn relay, hazard relay, starter interrupt relay > OFF
Condition 4
Condition
Description
Initial Condition
AUTOLOCK3 state
Event
TIMER DISABLED LIFTGATE OPEN
Action
Enter PREARM state
Autolock Time3 mode Condition 1
Condition
Description
Initial Condition
AUTOLOCK3 state
Event
Specification non-SMK:
TX LIFTGATE
Specification SMK:
RKE LIFTGATE=1
Action
AUTOLOCK3 maintenance and
Hazard twice ON (0.5 s ON / 0.5 s OFF)
Condition 2
Condition
Description
Initial Condition
ARM state
Event
Specification non-SMK:
TX LIFTGATE
Specification SMK:
RKE LIFTGATE=1 or passive LIFTGATE
Action
Enter AUTOLOCK3 state and hazard relay twice (0.5 s ON / 0.5 s OFF)
Condition 3
Condition
Description
Initial Condition
ARMWAIT state
Event
Specification non-SMK:
TX LIFTGATE
Specification SMK:
RKE LIFTGATE=1
Action
Enter AUTOLOCK3 state and hazard relay twice (0.5 s ON / 0.5 s OFF)
?
Test yourself
A quick Hyundai Tucson LM quiz: every answer comes with an explanation and a link to the manual page.