Service Highlight

Hybrid Control Unit (HCU) Schematic diagrams

~4min read

HCU Terminal And Input/Output Signal

Terminal Function

Connector [C133-S]

Pin No. Description Connected to
1 HCU ground Chassis ground
2 HCU ground Chassis ground
3 HCU ground Chassis ground
4 Battery power (B+) Battery
5 Battery power (B+) Battery
6 Battery power (B+) Battery
7 -
8 -
9 -
10 -
11 -
12 -
13 -
14 -
15 Brake Switch 2 signal input Brake Switch (NC, IG1)
16 Brake Switch 1 signal input Brake Switch (NO, B+)
17 -
18 -
19 -
20 -
21 -
22 -
23 -
24 -
25 -
26 -
27 -
28 -
29 -
30 -
31 -
32 -
33 -
34 -
35 -
36 -
37 -
38 Start signal input Inhibitor Switch
39 -
40 -
41 -
42 -
43 -
44 -
45 -
46 -
47 -
48 -
49 -
50 -
51 -
52 -
53 -
54 -
55 -
56 -
57 -
58 -
59 -
60 -
61 -
62 -
63 -
64 -
65 -
66 -
67 -
68 -
69 -
70 -
71 -
72 -
73 IGN signal input Smart Key Unit
74 -
75 L - CAN [High] Engine clutch Actuator
76 L - CAN [Low] Engine clutch Actuator
77 -
78 Powertrain CAN [High] Other control modules
79 Powertrain CAN [Low] Other control modules
80 -
81 Hybrid CAN [High] Other control modules
82 Hybrid CAN [Low] Other control modules
83 -
84 -
85 -
86 -
87 -
88 -
89 -
90 -
91 -
92 -
93 -
94 -

Input/Output signal

Connector [C133-S]

Pin no. Description Condition Type Level
1 HCU ground Always DC Voltage Max. 50mV
2 HCU ground Always DC Voltage Max. 50mV
3 HCU ground Always DC Voltage Max. 50mV
4 Battery power (B+) Always DC Voltage Battery Voltage
5 Battery power (B+) Always DC Voltage Battery Voltage
6 Battery power (B+) Always DC Voltage Battery Voltage
7 -
8 -
9 -
10 -
11 -
12 -
13 -
14 -
15 Brake Switch 2 signal input IG ON DC Voltage Battery Voltage
16 Brake Switch 1 signal input Always DC Voltage Battery Voltage
17 -
18 -
19 -
20 -
21 -
22 -
23 -
24 -
25 -
26 -
27 -
28 -
29 -
30 -
31 Sensor power (+5V) IG ON DC Voltage 4.9 - 5.1V
32 Sensor ground IG ON DC Voltage Max. 50mV
33 Clutch Pressure Sensor (CPS) signal input IG ON Analog 0.5 - 4.5V
34 -
35 -
36 -
37 -
38 Start signal input IG ST DC Voltage Battery Voltage
39 -
40 -
41 -
42 -
43 -
44 -
45 -
46 -
47 -
48 -
49 -
50 -
51 -
52 -
53 -
54 -
55 -
56 -
57 -
58 -
59 -
60 -
61 -
62 -
63 -
64 -
65 -
66 -
67 -
68 -
69 -
70 -
71 -
72 -
73 IGN signal input IG ON DC Voltage Battery Voltage
74 -
75 L - CAN [High] IG ON Pulse
76 L - CAN [Low] IG ON Pulse
77 -
78 Powertrain CAN [High] IG ON Pulse Dominant:2.75 - 4.5(3.5)V
Receive:2.0 - 3.0(2.5)V
79 Powertrain CAN [Low] IG ON Pulse Receive:2.0 - 3.0(2.5)V
Dominant:0.5 - 2.25(1.5)V
80 -
81 Hybrid CAN [High] IG ON Pulse Dominant:2.75 - 4.5(3.5)V
Receive:2.0 - 3.0(2.5)V
82 Hybrid CAN [Low] IG ON Pulse Receive:2.0 - 3.0(2.5)V
Dominant:0.5 - 2.25(1.5)V
83 -
84 -
85 -
86 -
87 -
88 -
89 -
90 -
91 -
92 -
93 -
94 -

Circuit Diagram