Service Highlight

Hybrid Starter Generator(HSG) Repair procedures

17steps
~102min
4/5difficulty
0204060801004936N·mlb·ft
Tightening torque found on this page
Done 0 of 17

Inspection

  1. Inspect the resistance line to line using mΩ tester.

    Item Pin Specification Remarks
    Resistance
    (Line - Line)
    U - V Average ± 5% At room temperature 68°F (20°C)
    V - W
    W - U

  2. Inspect the temperature sensor resistance.

    Item Pin Specification Remarks
    Resistance
    (Temperature sensor)
    4 - 9 121.6 - 133.14 kΩ At room temperature 68°F(20°C)

  3. Inspect the resolver sensor resistance.

    Item Pin Specification Remarks
    Resistance
    (Resolver sensor)
    1 - 4 11.7Ω ± 10% At room temperature 68°F (20°C)
    2 - 5 32Ω ± 10%
    3 - 6 30Ω ± 10%

  4. Inspect the insulation resistance.

    Item Inspection area Specification Remarks
    Insulation resistance
    (Housing, Cover)
    Motor Pin U - GND
    Pin V - GND
    Pin W - GND
    GND DC 540 V, 1 min
    5 mA↓ AC 1600V, 1 min
    Resolver sensor Pin 1 - GND
    Pin 2 - GND
    Pin 3 - GND
    10 MΩ↑ DC 500 V, 1 min
    Temperature sensor Pin 4 - GND 10 MΩ↑

Removal

  1. Shut off the high voltage circuit.

    ( Refer to Hybrid Motor System - "High Voltage Shut-off Procedure")

  2. Drain the coolant of hybrid cooling system.

    (Refer to Hybrid Motor Cooling System - "Coolant")

  3. Remove the air cleaner assembly.

    (Refer to Engine Mechanical System - "Air Cleaner")

  4. Remove the drive belt.

    (Refer to Engine Mechanical System - "Drive Belt")

  5. Remove the drive belt tensioner.

    (Refer to Engine Mechanical System - "Drive Belt Tensioner")

  6. Remove the idler.

    (Refer to Engine Mechanical System - "Idler")

  7. Disconnect the HSG connector (A).

  8. Separate the cooler hose (A) from the HSG.

  9. Remove the intake manifold

    (Refer to Engine Mechanical System - "Intake Manifold")

  10. Loosen the HSG mounting nut (A) and bolt (B).

    Tightening torque : 44.1 - 49 N·m

  11. Remove the HSG after removing the HSG bracket (A).

    Tightening torque : 55.9 - 61 N·m

Installation

  1. Install in the reverse order of removal.

  2. Perform the procedure below after installing.

    1. Refill the hybrid cooling system with coolant and bleed air from the hybrid cooling system using GDS.

      (Refer to Hybrid Motor Cooling System - "Coolant")

    2. Perform the engine clutch / motor resolver adaptation using the KDS/GDS.