Heating, Ventilation and Air Conditioning

Mode Control Actuator Repair procedures

16steps
~96min
4/5difficulty
Done 0 of 16

Inspection

  1. Switch "OFF" the ignition.

  2. Disconnect the mode control actuator connector.

  3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 7.

    Verify that the mode control actuator operates to the vent mode when connected in reverse.

    Mode control actuator [LH]

    1. -
    2. -
    3. Vent mode
    4. Sensor ground
    5. Feedback signal
    6. Sensor (+ 5V)
    7. Defrost mode

    Mode control actuator [RH]

    1. -
    2. -
    3. Vent mode
    4. Sensor ground
    5. Feedback signal
    6. Sensor (+ 5V)
    7. Defrost mode
  4. Connect the mode control actuator connector.

  5. Switch "ON" the ignition.

  6. Check the voltage between terminals 4 and 5.

    Specification

    Door position Voltage (V) Error detecti
    Vent 0.3 ± 0.15 Low voltage : 0.1V or less
    Defrost 4.7 ± 0.15 High voltage : 4.9V or more

    It will feedback the current position of the actuator to controls.

  7. If the measured voltage is not within specification, substitute with a known-good mode control actuator and check for proper operation.

  8. Replace the mode control actuator if it is proved that there is a problem with it.

Replacement

[Driver side]

  1. Disconnect the negative (-) battery terminal.

  2. Remove the main crash pad assembly.

    (Refer to Body - "Main Crash Pad Assembly".)

  3. Remove the driver side shower duct (A) after loosening the screw.

  4. Install in the reverse order of removal.

[Passenger side]

  1. Disconnect the negative (-) battery terminal.

  2. Remove the main crash pad assembly.

    (Refer to Body - "Main Crash Pad Assembly")

  3. Disconnect the connector and then remove the mode control actuator (A) after loosening the mounting screws.

  4. Install in the reverse order of removal.