Motor Control Unit (MCU) Repair procedures
Removal
Shut off the high voltage circuit.
( Refer to Hybrid Motor System - "High Voltage Shut-off Procedure")
Drain the coolant of hybrid cooling system.
(Refer to Hybrid Motor Cooling System - "Coolant")
Remove the air cleaner assembly.
(Refer to Engine Mechanical System - "Air Cleaner")
Remove the HPCU cover (A).

Remove the reservoir.
(Refer to Hybrid Motor Cooling System - "Reservoir")
Separate the hose (A) and loosen the bolt (B).
Tightening torque : 7.8 - 11,8 N·m

Remove the LDC power cable (A) and ground cable (B).
Tightening torque :
(A) 7.8 - 11,8 N·m
(B) 10.8 - 13,7 N·m

Disconnect the drive motor high voltage cable connector (A) and HSG high voltage cable connector (B) and then remove the wiring mounting clip (C).

Disconnect the high voltage battery cable connector (A) and the inverter high voltage cable connector (B).

Disconnect the HCU & MCU connector (A).

Remove the HCPU (A).
Tightening torque : 21.6 - 24 N·m

Installation
Install in the reverse order of removal.
Perform the procedure below after installing.
Refill the hybrid cooling system with coolant and bleed air from the hybrid cooling system using KDS/GDS.
(Refer to Hybrid Motor Cooling System - "Coolant")
Perform the engine clutch / motor resolver adaptation using the KDS/GDS.