Hybrid Motor System

Resolver Sensor Repair procedures

4steps
~24min
2/5difficulty
Done 0 of 4

Inspection

Hybrid Drive Motor

  1. Inspect the resolver sensor resistance.

    Item Pin Specification Remarks
    Resistance
    (Resolver sensor)
    1 - 5 11.7 Ω ± 10 % At room temperature 68°F (20°C)
    2 - 6 34.5 Ω ± 10 %
    3 - 7 29.5 Ω ± 10 %

  2. If the resolver sensor needs to be replaced, replace the hybrid drive motor assembly.

    (Refer to Hybrid Motor Assembly - "Hybrid Drive Motor Assembly")

Hybrid Starter Generator (HSG)

  1. Inspect the resolver sensor resistance.

    Item Pin Specification Remarks
    Resistance
    (Resolver sensor)
    1 - 4 13.8 - 17.8 Ω At room temperature 68°F (20°C)
    2 - 5 26.2 - 30.2 Ω
    3 - 6 26.2 - 30.2 Ω

  2. If the resolver sensor needs to be replaced, replace the HSG assembly.

    (Refer to Hybrid Motor Assembly - "Hybrid Starter Generator")

Resolver Calibration

Perform the resolver calibration using the KDS/GDS after replacing or reinstalling the below components.

  • Hybrid Drive Motor installation

  • Hybrid Starter Generator (HSG) installation

  • Motor Control Unit (MCU) replacement

  • Engine clutch system replacement