Heating, Ventilation, and Air Conditioning
Heater and Air Conditioning Control Unit (FATC) Repair Procedures
In this manual: Heating, Ventilation, and Air Conditioning
5steps
~30min
2/5difficulty
Done 0 of 5
Self-Diagnosis
- Self-Diagnosis Procedure
- How to Read Self-Diagnosis Codes After the display panel flashes three times every 0.5 seconds, the corresponding trouble code flashes in the set temperature display panel every 0.5 seconds and shows two digits. Codes are displayed in numeric format.
- Trouble Code Display
- Continuous Operation: DTC for One Code.
- Continuous Operation: DTC for Two or More Codes.
- STEP Operation
A. Same as continuous operation in normal mode or with one trouble code. B. DTC for Two or More Codes.
- Continuous Operation: DTC for One Code.
- If trouble codes are displayed during inspection, check the possible causes of the malfunction by referring to the trouble codes.
Self-Diagnosis Code Description of the problem Trouble Code 00 Normal - 11 INCAR SENSOR Open
(OPEN, INCAR F/B voltage is greater than or equal to 4.9 V)B1234 12 INCAR SENSOR Short
(SHORT, INCAR F/B voltage is less than or equal to 0.1 V)B1233 13 AMBIENT SENSOR Open
(OPEN, AMBIENT F/B voltage is greater than or equal to 4.9 V)B1238 14 AMBIENT SENSOR Short
(SHORT, AMBIENT F/B voltage is less than or equal to 0.1 V)B1237 17 EVAPORATOR SENSOR Open
(OPEN, EVAP F/B voltage is greater than or equal to 4.9 V)B1242 18 EVAPORATOR SENSOR Short
(SHORT, EVAP F/B voltage is less than or equal to 0.1 V)B1241 19 DRIVER TEMPERATURE DOOR POTENTIOMETER Open/Short
Open range: Temp F/B voltage is greater than or equal to 4.9 V
Short range: Temp F/B voltage is less than or equal to 0.1 VB1245 (open)
B1246 (short)20 DRIVER TEMPERATURE DOOR POTENTIOMETER Malfunction B2406 21 DR MODE DOOR POTENTIOMETER Open/Short
Open range: DR MODE F/B voltage is greater than or equal to 4.9 V
Short range: DR MODE F/B voltage is less than or equal to 0.1 VB1249 (open)
B1250 (short)22 DR MODE DOOR POTENTIOMETER Malfunction B2409 23 AUTO SENSOR Open B1282 24 AUTO SENSOR Short Circuit B1281 25 INTAKE DOOR POTENTIOMETER Open/Short
Open range: INTAKE F/B voltage is greater than or equal to 4.9 V
Short range: INTAKE F/B voltage is less than or equal to 0.1 VB1208 (open)
B1209 (short)26 INTAKE DOOR POTENTIOMETER Malfunction B2408 27 PS MODE DOOR POTENTIOMETER Open/Short
Open range: PS MODE F/B voltage is greater than or equal to 4.9 V
Short range: PS MODE F/B voltage is less than or equal to 0.1 VB1206 (open)
B1207 (short)28 PS MODE DOOR POTENTIOMETER Malfunction B2416 33 DEF DOOR POTENTIOMETER Open/Short
Open range: DEF F/B voltage is greater than or equal to 4.9 V
Short range: DEF F/B voltage is less than or equal to 0.1 VB1283 (open)
B1284 (short)34 DEF DOOR POTENTIOMETER Malfunction B1285 48 VEHICLE SPEED CAN Signal Error B1686 50 CLUSTER Ionizer Error
[DIAG signal voltage less than 2.0 V]B1688 51 DUCT SENSOR-DR VENT Open
(OPEN, DR VENT DUCT SENSOR voltage greater than 4.9 V)B2187 52 DUCT SENSOR-DR VENT Short
(SHORT, DR VENT DUCT SENSOR voltage less than 0.1 V)B1286 53 DUCT SENSOR-DR FLOOR Open
(OPEN, DR FLOOR F/B DUCT SENSOR voltage greater than 4.9 V)B1289 54 DUCT SENSOR-DR FLOOR Short
(SHORT, DR FLOOR F/B DUCT SENSOR voltage less than 0.1 V)B1288 61 Ecomp_Wait_Communication Loss B1807 62 Ecomp_Wait_Low Voltage B1821 63 Ecomp_Wait_High_Voltage B1822 64 Ecomp_Wait_Over_Heat_Protection B1823 65 Ecomp_Wait_Over_Current_Protection B1824 66 Ecomp_Wait_Low_Temp_Protection B1825 67 Communication Lost with E-Comp B160B 68 Ecomp_Sleep_Missed_Restart B1826 69 Ecomp_Sleep_Current Sensor Malfunction B1827 70 Ecop_Fault_Short Circuit B182B 71 PTC HTR_LV_Low Malfunction B182E 72 PTC HTR_LV_High Malfunction B182F 73 PTC HTR_HV_Low Malfunction B1830 74 PTC HTR_HV_High Malfunction B1831 75 PTC HTR_Over Current Fault B1832 76 PTC HTR_Thermal Cutoff Malfunction B1833 77 PTC HTR_PCB Thermal Cutoff Malfunction B1834 79 PTC HTR_High Voltage Sensor Malfunction B1835 80 PTC HTR_Low Voltage Sensor Malfunction B1836 81 PTC HTR_Current Sensor Malfunction B1837 82 PTC HTR_PCB Temperature Sensor Open/Short B1838 83 PTC HTR_Internal Temperature Sensor Open/Short B1839 84 Communication Lost with PTC B160K 85 E-COMP Lock Circuit OPEN B2470 86 High Voltage PTC Lock Circuit OPEN B1818 87 2-Way Valve No. 2 OPEN B1858 88 2-Way Valve No. 2 SHORT B1859 89 2-Way Valve No. 1 OPEN B1856 90 2-Way Valve No. 1 SHORT B1857 91 3-Way Valve No. 1 OPEN B1850 92 3-Way Valve No. 1 SHORT B1851 93 3-Way Valve No. 2 OPEN B1852 94 3-Way Valve No. 2 SHORT B1853 95 FATC C-CAN Bus Off B1603 96 CAN MCU2 or MCU3 Message Timeout B2210 97 VCU1, VCU5 or VCU10 CAN Message Timeout B2209 98 BMS1 CAN Message Timeout B2211 101 Refrigerant Temperature Sensor (RTS) #1 Open
(OPEN, RTS #1 F/B voltage above 4.9 V)B184A 102 Refrigerant Temperature Sensor (RTS) #1 Short
(SHORT, RTS #1 F/B voltage below 0.1 V)B184B 103 Refrigerant Temperature Sensor (RTS) #2 Open
(OPEN, RTS #2 F/B voltage above 4.9 V)B184C 104 Refrigerant Temperature Sensor (RTS) #2 Short
(SHORT, RTS #2 F/B voltage below 0.1 V)B184D 105 APT Sensor Open
(OPEN, APT SENSOR F/B voltage below 0.1 V)B1819 106 APT Sensor Short
(SHORT, APT SENSOR F/B voltage above 4.5 V)B1820 107 Blower Motor Locked B1804 108 Coolant Valve Stuck Open B185A 109 Coolant Valve Short or Stuck B185B - Fail-safe
No. SIGNAL Fail-Safe Mode Malfunction Notes 1 INCAR Sensor Short Fix to 25 °C Check the signal line. 2 INCAR Sensor Open Fix to 25 °C Check the signal line. 3 AMBIENT Sensor Short "--" displayed on screen
Alternative control to 20 °CCheck the signal line. 4 AMBIENT Sensor Open "--" displayed on screen
Alternative control to 20 °CCheck the signal line. 5 EVAPORATOR Sensor Short Fix to -2°C Check the signal line. 6 EVAPORATOR Sensor Open Fix to -2°C Check the signal line. 7 DRIVER TEMPERATURE DOOR POTENTIOMETER Short If the driver set temperature is below 24 °C, set cold temperature; if it is above 25 °C, set warm temperature. Check the signal line. 8 DRIVER TEMPERATURE DOOR POTENTIOMETER Open Check the signal line. 9 DRIVER TEMPERATURE DOOR POTENTIOMETER Malfunction Fix to current position Check the DC motor or door lock. 10 DR MODE DOOR POTENTIOMETER Short For VENT mode, fix to VENT position; otherwise, fix to DEF position. Check the signal line. 11 DR MODE DOOR POTENTIOMETER Open Check the signal line. 12 DR MODE DOOR POTENTIOMETER Malfunction Fix to current position Check the DC motor or door lock. 13 INTAKE DOOR POTENTIOMETER Short If FRE is selected, fix to FRE position; if REC is selected, fix to REC position. Check the signal line. 14 INTAKE DOOR POTENTIOMETER Open Check the signal line. 15 INTAKE DOOR POTENTIOMETER Malfunction Fix to current position Check the DC motor or door lock. 16 AUTO SENSOR Short Circuit Release advertisement Check the signal line. 17 AUTO SENSOR Open Release advertisement Check the signal line. 18 PS MODE DOOR POTENTIOMETER Short For VENT mode, fix to VENT position; otherwise, fix to DEF position. Check the signal line. 19 PS MODE DOOR POTENTIOMETER Open
Components and Component Locations of Heater and Air Conditioning Control Unit (FATC)
Components Function Pin No. Connector A Connector B Connector C 1 ILL (+) Ground Electric Compressor Lock (+) 2 Sensor REF (+5V) Sensor Ground Electric Compressor Lock (-) 3 C_CAN High ...
Electric Vehicle Battery System
... Additional information:
Kia Soul EV (PS EV) 2015-2020 Service Manual: Front Seat Outer Cover Repair Procedures
Replacement • Wear gloves to protect your hands. • When prying with a flat-blade screwdriver, wrap its tip with protective tape and apply protective tape around the corresponding parts to prevent damage. • Nas ...
Kia Soul EV (PS EV) 2015-2020 Service Manual: General Information
Vehicle Identification Numbers Identification Number Description Vehicle Identification Number 1. World Manufacturer Identifier (WMI) - KNA: Passenger Car, MPV (Multi-Purpose Passenger Vehicle)/SUV (Sport Utility Vehicle)/RV (Recreational Vehicle) - KNC: Commercial Vehicle (Van) - KND: MPV/SUV/...
Test yourself
A quick Kia Soul EV Owner's Manual quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?