5steps
~30min
2/5difficulty
Done 0 of 5
Inspection
- Press the VENT switch more than 4 times within 2 seconds while pressing the OFF switch.
Display Description of Malfunction 00 Normal 50 Cluster Ionizer Generator Malfunction
* For the diagnostic procedure, refer to the DTC Chart.
Replacement
- Disconnect the negative (-) battery terminal.
- Remove the glove box housing. (Refer to Body - "Glove Box Housing")
- Remove the shower duct (A).

- Disconnect the connector, then remove the cluster ionizer (B) after loosening the mounting screws.

- Install in the reverse order of removal.