Body Electrical System
Description and Operation
In this manual: Body Electrical System
6steps
~36min
2/5difficulty
Done 0 of 6
Window Safety Force Function
When the driver's door window auto-up switch is operated, the safety function is active.- Safety Function Condition: When a force of 100 N (using a 10 N/mm spring) is detected while the window is closing, the window reverses.
- Window reverse distance (except when holding the auto-up switch)
- When a pinch is detected at a distance of 4–250 mm from the top of the door. → The window reverses to 300 mm from the top of the door.

- When a pinch is detected at a distance of more than 250 mm from the top of the door. → The window reverses to 20 mm from the pinch position.

- When a pinch is detected at a distance of 4–250 mm from the top of the door. → The window reverses to 300 mm from the top of the door.
- Window reverse distance (holding the auto-up switch)
- When a pinch is detected while holding the auto-up switch: the window reverses to 25 mm from the pinch position.
- The auto-up function is unavailable for 5 seconds under the above condition. → When the auto-up switch is held, the window operates as a manual function. (The safety function is not activated.)
- When the auto-up switch is held for 5 seconds from the above condition. → The window reverses to 25 mm from the pinch position.

- Safety function not available. The safety function is not available within 4 mm from the top of the door.
- Battery Connection Initialization: When battery power has been disconnected for more than 5 minutes, the power window safety switch must be initialized.
- Window Operation Before Initialization
- Manual up/down function is available.
- Auto-up function is unavailable. (When the auto-up/down switch is held, the window operates as manual up/down.)
- Initialization Method: Close the window from the open position, and hold the switch in the fully closed position of the window for 2 seconds. (If the window closing is started from the fully closed position, initialization may fail.)
- If the power window safety function is initialized while the window is pinched, the following conditions may occur.
- Safety Function Not Available
- Window Operation Before Initialization
- Fail-Safe Mode Initialization
- If the window is forced to move and the motor is faulty, the window switch may enter fail-safe mode to ensure user safety.
- Power Window Operation in Fail-Safe Mode
- Auto/Manual-Down function is available.
- Auto/Manual-Up function unavailable (With auto/manual up, the glass rises 20 mm and stops moving.)